PanelSimulator Academy

Perimeter Protection, lesson 5 of 8

Outdoor detection

Lesson 1 showed that a fence without detection only delays an intruder in private. This lesson covers the sensors that turn a crossing into an alarm: cable on the fence, beams between posts, cable under the ground and radar over open land. Each one notices in a different place and is fooled by different things, and choosing well means matching the sensor to the ground it has to watch.

About 14 minutes. Read lessons 1 and 2 first.

Where each sensor notices

Pick a sensor, then play or step through. The shaded shape is the space it watches.

outside inside the site a slice through the fence line, seen from the side radar on a pole two buried cables beam tower: four beams run along the fence, toward you sensor cable on the fabric Fence

The everyday picture

A spider does not watch its web. It rests one leg on a thread and feels the web shake. A shop does it differently: a small beam crosses the doorway and a bell rings when you break it. A porch light does it a third way, coming on when something warm moves anywhere on the driveway.

Those are the main ideas in outdoor detection. Feel the barrier move, watch a line being broken, or watch a whole area. The first two tell you someone is at the line. The third can tell you someone is coming.

Three numbers that describe a sensor

  • Probability of detection. Out of 100 real crossings, how many raise an alarm? No sensor scores 100, and the figure depends on how the crossing is made and how well the sensor was installed.
  • Nuisance alarm rate. How often the sensor alarms for a real cause that is not an intruder: wind, a rabbit, a passing truck. Lesson 7 is about these.
  • False alarm rate. How often it alarms for no outside cause at all, because of a fault in the equipment.

The first two pull against each other. Turn the sensitivity up and you catch more intruders and more rabbits. Turn it down and both fall. A sensor that cries wolf ten times a night will be ignored or switched off, and then its probability of detection is zero. So a designer aims for a sensor that is quiet in this particular place.

Four families

  • Fence-mounted sensors. A cable tied to the fabric, or small sensors on the posts, pick up the vibration and flexing caused by someone climbing, cutting or lifting the fence. Cables may be electrical or fiber optic. They are the cheapest way to cover a fence you already have, and they only work on a fence that is tight and quiet.
  • Beams. A transmitter sends infrared light or microwaves to a receiver some distance away, and anything that blocks the path raises an alarm. Infrared units, called photoelectric beams, are stacked in towers to make a tall, thin invisible wall. A microwave link makes a fatter zone several feet wide. Both need a straight, level line of sight.
  • Buried cable. A pair of cables a few inches under the ground set up an invisible field above them, a few feet wide and about waist high. A person crossing disturbs it. Nothing shows above ground, and the zone follows curves and gentle slopes.
  • Radar and thermal cameras. A radar unit sweeps open ground and reports anything that moves, with its position. A thermal camera with video analytics does a similar job by picking warm, moving shapes out of the picture. These watch an area, so they can warn you before anyone reaches the fence.

Check yourself

Which sensor can raise an alarm while a person is still 200 feet outside the fence?

Side by side

Fence sensorBeamsBuried cableRadar
It noticesThe fence being disturbedA path being blockedA field being disturbedMovement in open space
Shape watchedThe fence itselfA straight, narrow wallA low band that follows the groundA wide area
Can be seenYes, if you lookYesNoYes
Ground it needsA sound, tight fenceStraight, flat, clear line of sightStable, well-drained soil or pavingOpen view with few obstructions
Design limitSees nothing that does not touch the fenceOnly as tall and as low as its beamsOnly as wide as its fieldBlind behind buildings, dips and parked vehicles
Relative costLowestLow to mediumHigh, mostly diggingHigh per unit, but one unit covers a lot

Read the "design limit" row as a to-do list. A fence sensor needs every gap under and around the fence closed, as lesson 2 described. Beam towers need enough beams to cover from near the ground to above head height, and ground with no dips beneath the lowest beam. A buried cable works best with a fence in front of it, so that nobody wanders across by accident. Radar needs its blind spots found on a site plan and filled with a second unit or another sensor.

Ranges differ widely between products. A single beam pair or microwave link commonly covers a few hundred feet. Radar units range from about a hundred feet to well over a thousand. Take the figure from the data sheet, and then use less than the maximum: beams at the limit of their range are the first to drop out in fog.

Two different sensors beat one

High-security sites put two sensors of different kinds on the same line, such as a fence sensor and a microwave link just inside it. Wind bothers the first and not the second. A rabbit bothers the second and not the first. The system can then be set to alarm when both trip within a few seconds, which cuts nuisance alarms sharply, or when either trips, which raises the chance of detection. You cannot have both benefits at once.

Zones, and seeing what tripped

A perimeter sensor is divided into zones, lengths that report separately. An alarm that says "north fence, zone 7" is useful. An alarm that says "perimeter" sends a guard on a half-mile walk.

An alarm by itself also says nothing about its cause. Someone has to look. This step is called assessment, and it is usually done with a camera aimed along each zone that pops up on the operator's screen when that zone trips. So a zone should be no longer than a camera can usefully show, and straight, so that the camera can see all of it. A common working length is around 300 feet. Some newer fence and fiber sensors go further and report the spot to within a few yards, which lets a moving camera turn straight to it.

Design choiceWhy
End a zone at every corner and gateA camera cannot see round a corner, and a gate needs its own rules by day
Give each gate its own zoneSo it can be switched off while the gate is in use without blinding the fence beside it
Overlap neighboring zones slightlySo there is no dead spot where one ends and the next begins
Protect the sensor's own cable and cabinetsA cut cable or opened box should raise a tamper alarm, as an indoor system does

Divide a perimeter into zones

How many zones?

Count each straight side separately, because a zone should not bend round a corner.

feet of perimeter
fence zones
zones in all, with gates
fixed cameras to assess them

Three examples

Simple: the car dealer's lot

A dealer's lot has a low decorative rail along the street and no fence that could carry a sensor. Catalytic converters are being stolen at night. The installer fits two pairs of photoelectric beam towers along the street side, each covering about 200 feet of straight, level paving, and links them to lights and a loudspeaker.

The beams work because the ground is flat and paved, so nothing grows into the path. The dealer is told to keep the row of cars for sale behind the beam line, not across it.

Medium: the fence that sang

A warehouse adds a sensor cable to its old chain link fence. From the first windy night it alarms every few minutes. The supplier turns the sensitivity down until it stops, and now a person shaking the fence by hand does not trip it either.

The sensor was fine. The fence was loose, a banner was tied to it, and a tree branch rubbed one panel. The fix was to tighten the fabric, add ties, move the banner and trim the tree, then set the sensitivity back up and test every zone by hand.

Advanced: the solar farm

A solar farm covers 200 acres, with about 12,000 feet of fence and nobody on site. A fence sensor at 300 feet a zone would mean 40 zones and 40 cameras, with power and data to each.

The designer uses four radar units on poles instead, each paired with one moving thermal camera. When radar reports a track, the camera turns to it and the picture goes to a monitoring center. Sheep graze the site, so the radar is set to ignore slow, low targets inside the grazing paddocks, and the designer checks on the plan that rows of panels do not hide the fence line from every unit. The fence stays as a plain marker and delay.

From the field

  • Fix the fence before you fit the sensor. Tight fabric, firm posts, nothing tied on, nothing rubbing.
  • Walk-test every zone at handover and write down the result. Test it the ways the customer cares about, in daylight and after dark.
  • Keep vegetation out of every zone. A strip of gravel or weed barrier under beams and along a sensor fence pays for itself.
  • Mount beam towers on their own posts in concrete, never on the fence. A post that moves in the wind drags the beam off its receiver.
  • Bring surge protection. Long outdoor cables and tall poles collect lightning energy. Protect both ends of every cable that leaves a building.

Common mistakes

  • Fitting a fence sensor to a loose or noisy fence, then turning it down until it is deaf.
  • Running beams across ground that dips, or using a pair at its maximum range.
  • Zones too long to assess, or zones that bend round a corner.
  • Detection with no camera and no person to look, so every alarm is a guess.
  • No gate zone, so the whole side is switched off whenever the gate is open.

Summary

  • Fence sensors feel the fence. Beams watch a line. Buried cable watches a hidden band. Radar and thermal cameras watch an area.
  • Sensitivity trades detection against nuisance alarms. Choose the sensor that is naturally quiet on this site.
  • Every sensor has a shape it watches and a limit. Design the site to fit the shape.
  • Divide the line into short, straight zones, each with a way to see what tripped it.
  • Two different kinds of sensor on one line cover each other's weak points.

Exercises

Answer each one yourself first, then open the answer.

Exercise 1. What is the difference between a nuisance alarm and a false alarm?

Show answer
A nuisance alarm has a real outside cause that is not an intruder, such as wind or an animal. A false alarm has no outside cause: the equipment itself is at fault.

Exercise 2. A rectangular site has two sides of 900 feet and two of 450 feet, with one gate. With zones of 300 feet at most, how many zones are there?

Show answer
Each 900-foot side needs 3 zones and each 450-foot side needs 2, because 450 divided by 300 rounds up. That is 3 + 3 + 2 + 2 = 10 fence zones, plus 1 for the gate: 11.

Exercise 3. Why should beam towers not be fixed to the fence?

Show answer
The fence moves in the wind and when it is touched. A beam is a narrow line aimed at a receiver hundreds of feet away, so a small movement of the tower swings the beam off target and raises an alarm.

Exercise 4 (think, don't memorize). A museum wants detection around its sculpture garden. Visitors must not see fences or equipment, the ground is lawn with mature trees, and the garden is closed at night. Which sensor would you look at first, and what would you check?

Show answer
Buried cable, because it is the only family with nothing above ground. Check the soil and drainage, since standing water changes the field. Check tree roots and where gardeners dig, since the cable is only inches down. Route it away from metal fences and buried pipes if the maker says so. Plan how each zone will be assessed at night, which probably means discreet thermal cameras, and arm it by schedule so that daytime visitors do not trip it.