Installation, Commissioning and Maintenance, lesson 2 of 10
Tools and test equipment
A technician's bag holds two kinds of thing: tools that make a connection, and instruments that prove it. The first kind gets the job done. The second kind is what lets you say "this works" and be right. This lesson goes through both, and spends most of its time on the one instrument you will use every day.
Put the meter on a circuit
Choose what to measure. Watch the dial, the jack the red lead sits in, and where the probes touch.
The everyday picture
A cook does not own a hundred knives. A good cook owns five, keeps them sharp and knows what each is for. A cook also owns a thermometer, because "it looks done" is a guess and 165 degrees is a fact.
Your bag works the same way. A small set of hand tools, each matched to the wire and screws you meet, does almost all the physical work. A few instruments replace guessing with a number. The most common sentence in fault finding is "it should be working". The meter is how you find out whether it is.
Hand tools
| Tool | What it is for | The detail that matters |
|---|---|---|
| Wire stripper | Removing insulation without touching the copper | Use the notch marked with the wire's AWG size. Security wire is mostly 22 to 18 AWG. |
| Flush cutters | Cutting wire and trimming cable ties | A tie cut flush leaves no sharp stub to slice the next hand in the cabinet. |
| Terminal screwdriver | The small screws on controller and reader terminals | A narrow flat blade, about an eighth of an inch. A wider one chews the terminal block. |
| Security bit set | Tamper-resistant screws on readers and camera domes | Keep the bit that came in the device's box. You will need it at every service visit. |
| Crimping tool | Squeezing a connector onto a wire | Matched to the connector. Lesson 4 explains why pliers will not do. |
| Fish tape and glow rods | Getting a cable through a wall or across a ceiling | Rods screw together in sections and can be seen in a dark ceiling. |
| Drill and bits | Holes in wood, steel and masonry | A step bit makes clean holes in a steel door frame. Masonry needs a hammer drill. |
| Level, tape and pencil | Putting devices where the drawing says, and straight | A crooked reader is the first thing a customer sees. |
| Label printer | Naming every cable and device | Printed labels that wrap around the cable. Handwriting on tape fades and falls off. |
Add a headlamp, because cabinets and ceilings are dark and you need both hands. Add a ladder made of fiberglass, not aluminum, because you will work near electrical equipment.
Test equipment
- Multimeter Measures voltage, resistance, continuity and current. If you carry one instrument, carry this one. The tool at the top of the page shows its four main jobs.
- Tone generator and probe The generator puts a warbling tone on a cable. The probe, held near a bundle at the other end, sings when it is near the right one. It finds an unlabeled cable in minutes.
- Network cable tester Checks that all eight wires of a network cable reach the right pins. Better ones also show the length and whether Power over Ethernet is present, and how much.
- Camera test monitor A small battery screen that powers a camera and shows its picture while you are still on the ladder, so you aim and focus once.
- Test credentials A valid card, an expired card and a card with no access. You cannot prove that a door refuses the wrong people with a card that works everywhere.
- Laptop and adapters For programming. Carry a network cable, a small switch and whatever serial or USB adapter the equipment needs. Check before you drive to site.
Four rules for the meter
A multimeter has a dial that chooses what to measure and two leads. The black lead goes in the jack marked COM and stays there. The red lead goes in the jack marked for volts and ohms, except when measuring current.
- Voltage is measured across, with power on. Touch one probe to each side of the device, like a doctor holding a stethoscope to a chest. The circuit keeps running.
- Resistance and continuity are measured with power off. The meter sends its own tiny current through the wire. Disconnect at least one end from the equipment first, or you measure the equipment as well. Continuity is a resistance test with a beeper: a beep means an unbroken path.
- Current is measured in line. You open the circuit and put the meter in the gap, so that the current flows through it. The red lead moves to the jack marked A.
- Put the red lead back. In the A jack the meter is almost a plain piece of wire. Touch it across a power supply to "check the voltage" and you have made a short circuit. At best, the meter's fuse blows.
| You want to know | Dial | Power | Where the probes go |
|---|---|---|---|
| Is the lock getting enough voltage? | DC volts | On, lock working | Across the lock's two terminals |
| Is this conductor broken? | Continuity | Off, cable disconnected | On the pair at one end, with the far end joined |
| Is the end-of-line resistor there? | Ohms | Off, loop lifted from the panel | Across the loop's two wires |
| How much does this lock draw? | DC amps | On | In the gap of one opened wire |
On the resistance and continuity settings, a screen that reads OL means "over limit". The resistance is too high to measure, which nearly always means the path is open.
Before trusting a reading of zero volts, test the meter on something you know is live, such as the supply's output terminals. A meter with a flat battery, a blown fuse or a broken lead also reads zero. If you ever measure mains voltage, the meter and its leads must carry a safety category rating suited to that work, printed beside the jacks. If you are not trained for mains, leave it to someone who is.
Check yourself
You want to measure the resistance of a sensor loop. What state should the loop be in?
What is the meter telling you?
A reading is only useful once you turn it into a statement about the circuit. Try these.
Five readings, your diagnosis
Pick the most likely meaning of each reading, then read why.
Finding and proving cable
The tone generator, often called a toner, answers the question "which of these forty gray cables goes to Door 12?". Clip the generator to the cable at the door. In the cabinet, sweep the probe along the bundle. The tone is loudest on the right cable. Confirm by shorting the pair at the door for a moment: the tone should stop. Use a toner on dead, disconnected cable only, unless its instructions say otherwise.
Network cable needs its own tester because a meter cannot see how the pairs are arranged. Testers come in three grades:
- A basic wiremap tester lights up pins 1 to 8 in turn. It finds crossed, open and shorted wires, and costs little.
- A mid-grade tester adds cable length, the distance to a break, and a Power over Ethernet reading.
- A certifier measures the cable against the published standard for its category and prints a report. Large projects often require a certified report for every network cable. They are expensive, and often rented.
Remember what a simple tester does not prove. A cable can pass a wiremap test and still carry video badly because it is too long, kinked or poorly terminated. The Networking course covers Power over Ethernet in full. One habit belongs here: test a camera's cable before you climb, not after the camera fails to start.
Three examples
Simple: the lock that does nothing
A new strike will not release. Before changing anything, the technician sets the meter to DC volts, holds the probes on the strike's terminals and asks a colleague to present a card. The meter reads 0. At the cabinet, the same test on the lock output reads 24. The power leaves the cabinet and does not arrive, so the fault is in the cable or a joint. Two measurements have cleared the strike, the relay and the supply.
Medium: forty cables and no labels
A previous installer left a ceiling full of unlabeled cable. A new reader is going on an existing door, and its cable is somewhere in the bundle at the cabinet. Pulling on cables to see which one moves is how connectors get torn off working doors. The technician clips a toner on at the door, finds the cable with the probe in two minutes, confirms it with a short, and labels both ends before doing anything else.
Advanced: the camera that restarts at dusk
An outdoor camera goes offline every evening and comes back by itself. The picture is fine all day. A tester with a Power over Ethernet reading is put in line at the camera. In daylight the camera draws a modest amount. When the light fails, the camera switches on its infrared lamps and heater, the draw climbs, and the voltage at the camera sags until it restarts.
The cable is long and the switch port is providing all it was set up to provide. The instrument turned "it is haunted" into a number. The cure is a port that supplies the higher grade of power the camera's data sheet asks for, or a shorter run.
From the field
- Measure under load. A supply or battery can show full voltage with nothing connected and collapse when the lock pulls current. Take the reading while the device is working.
- Carry spare fuses and a spare battery for the meter. The fuse always blows at the far end of the site.
- Buy leads with sharp probe tips and a set of small clips. Clips free your hands and stop a probe slipping across two terminals.
- Keep a door magnet in your pocket. Holding it to a door contact tests the contact without opening the door.
- Write readings down. "23.1 volts at Door 6 lock, energized" in the commissioning record is worth more than a tick.
Common mistakes
- Measuring resistance on a circuit that is still powered. The reading is nonsense and the meter may be damaged.
- Leaving the red lead in the A jack and then measuring voltage.
- Trusting 0 volts from a meter that has not been checked on a live source.
- Stripping wire with cutters or a knife and nicking the copper.
- Using the meter's AC setting on a DC circuit and reading almost nothing.
- Arriving without the adapter the controller needs.
Summary
- Hand tools make connections. Instruments prove them.
- Voltage: across the device, power on. Resistance and continuity: power off, one end lifted. Current: in line, red lead in the A jack, then back.
- OL on a resistance setting means an open path.
- A toner finds a cable. A network tester proves its eight wires. A certifier proves it to the standard.
- Measure while the device is working, and write the number down.
Exercises
Answer each one yourself first, then open the answer. The tool at the top will help.
Exercise 1. Which jack does the black lead use, and when does it move?
Show answer
Exercise 2. You test a two-wire cable for continuity with the far end twisted together. The meter shows OL. Then you untwist the far end and it still shows OL. What have you learned?
Show answer
Exercise 3. A lock's data sheet says 0.5 amps at 24 volts. Your meter, in line, reads 0.24 amps and the lock holds weakly. Name one likely cause.
Show answer
Exercise 4 (think, don't memorize). A colleague says, "I checked the battery, it reads 13 volts, it is fine." Why is that not enough, and what would you do?