Intrusion Detection, lesson 12 of 12

Designing an intrusion system from a floor plan

You now know the sensors, the panel, zones, arming, wiring, radio, sounders, hold-up devices and false alarms. This last lesson puts them together. You will protect a small store, watch the parts list build itself, and learn the order in which a professional works.

About 16 minutes. Read the rest of the course first.

Protect this store

Click a numbered device to add or remove it. The parts list and the review update as you go.

counter Shop floor Stockroom Office display windows, street office window rear door, yard roll-up door panel keypad
    zones used
    panel needed
    drawn from the auxiliary power terminals
    cable, with 10% spare

      The everyday picture

      Someone who sets a mousetrap well does not start by buying traps. They look for where the mice come in, which way they run along the wall, and what they are after. Then two traps in the right places do more than ten scattered about.

      Designing an alarm system is the same kind of work. The question is never "how many sensors?" It is "how would someone get in, where would they go, and at which points am I certain to notice?"

      Ten steps from question to handover

      1. Ask what is being protected, from whom, and when the building is empty. Cash, stock, drugs, tools, data. Opening hours, cleaners, early deliveries.
      2. Walk the site, inside and out. Note every door, window, hatch, skylight and roll-up door. Look at what each is made of and how well it closes. Look for heaters, vents and pets.
      3. Mark the perimeter on a plan. Every opening an adult could get through is a candidate for a sensor.
      4. Add the interior layer. Place motion detectors where anyone moving through the building must pass.
      5. Trace how people come and go. Decide which doors are entry routes, where the keypads go, and how long the delays must be.
      6. Write the zone list. One zone per device where you can, each with a type, a partition and a name a stranger would understand.
      7. Add what people raise themselves: hold-up buttons, panic keys and duress codes, where the risk calls for them.
      8. Decide how the alarm is announced and reported: sounders, strobe, cutoff time, and the paths to the monitoring center.
      9. Choose wired or wireless for each device, then do the sums: zones, auxiliary current, battery and cable.
      10. Review for false alarms, install, walk-test every sensor, train every user, and hand over records.

      Think in layers

      A good design notices an intruder more than once. The first chance is at the building's skin. The second is inside. The last is at the thing they came for.

      LayerWhat it watchesTypical sensorsWhat it gives you
      PerimeterDoors, windows and other openingsContacts, glass-break and shock sensorsThe earliest warning, often before anyone is inside. Can stay armed while people are in the building.
      InteriorRooms and routesMotion detectorsA second chance that does not care how they got in, including through a wall or the roof.
      ObjectA safe, a cabinet, a display caseContacts, vibration sensorsProtection for the target itself, sometimes around the clock.
      PeopleStaff under threatHold-up buttons, panic keys, duress codesCover for the hours when the building is open and the other layers are off.

      The perimeter alone has gaps: a contact says nothing if the glass is cut out or a panel of the wall is removed. The interior alone is late: by the time a motion detector trips, the intruder is already inside. Together, each covers the other's blind side, and two zones tripping in sequence is the evidence that "False alarms" taught you to plan for.

      In the store above, switch off device 6 and read the review. Then switch 6 back on and switch off 4. The first leaves a hole in the skin. The second leaves the skin intact with nothing behind it.

      Check yourself

      A store has contacts on every door and window and no motion detectors. Which intruder does it miss?

      Give each zone a type

      A zone's type tells the panel how to react when that zone opens: wait, alarm at once, ignore in stay mode, or act around the clock. Names differ between makers, so read the manual, but the behaviors are the same. Pick a device to see the type it usually needs.

      Which type for which device?

      Watch for

      The zone schedule

      The zone schedule is the central document of an intrusion design. It has one row per zone and one column per decision. Installers wire from it, program from it and test against it, and the monitoring center's account is built from it.

      ZoneNameDeviceTypeWiringRun
      1Front doorRecessed contactEntry and exit delayWired, end-of-line170 ft
      2Shop glass-breakAcoustic glass-breakPerimeter, instantWired, 4 conductor120 ft
      3Shop floor motionDual-technology motionInterior, follows the entry routeWired, 4 conductor190 ft
      4Stockroom motionMotion detectorInterior, instantWired, 4 conductor70 ft
      5Rear doorSurface contact, steel door typePerimeter, instantWired, end-of-line100 ft
      6Roll-up doorOverhead-door contactPerimeter, instantWired, armored lead80 ft
      7Office motionMotion detectorInterior, instantWired, 4 conductor40 ft
      9Hold-up, counterTwo-button hold-up device24-hour silentWired, own zone130 ft

      Every column is a lesson from this course. If you can fill in a row and explain each entry, you can design that zone.

      Two more documents go with it: a floor plan marked with each device and cable route, and a list of users with their partitions and the people the monitoring center should call, in order.

      Three examples

      Simple: the store above

      With devices 1 to 7 and 9 on, the store uses eight zones, exactly filling an eight-zone panel. Every opening is covered, each room has a motion detector behind it, and the counter has a silent hold-up button. The design then needs an inside sounder, an outside siren with a strobe facing the street, and a battery sized as in "Sounders, strobes and outputs".

      Medium: staff who arrive by the back door

      The owner mentions that staff park in the yard and come in through the rear door. The only keypad is by the front door, about 70 feet away through the stockroom and across the shop floor. As designed, the rear door is an instant zone, so the first person in each morning would set off the alarm.

      The designer adds device 10, a second keypad just inside the rear door, changes the rear door to an entry and exit delay zone, and sets the stockroom motion detector to follow that entry route. The front door keeps its own delay. Asking how people really arrive changed three rows of the zone schedule.

      Advanced: designing for two tenants

      A year later the owner lets the office to an accountant, who gets a new street door where the office window was. The two businesses keep different hours.

      The designer splits the system into two partitions, as in "Zones and partitions". The office motion detector and the new door move to partition 2, with a keypad of their own. The door between shop and office gets a contact that belongs to both, so that it is watched whenever either side is armed. The panel was already full at eight zones, so a zone expander goes in the office, which also shortens the new cable runs. Had the first design left two zones spare, the same change would have needed no new hardware in the cabinet.

      From the field

      • Walk the site at closing time with the person who locks up. You will learn the real route, the door that sticks and where the keypad should be.
      • Look up. Skylights, roof hatches, ceiling voids shared with a neighbor and air-conditioning openings are part of the perimeter.
      • Number zones the same way on the plan, the schedule, the cable tags, the panel and the monitoring account.
      • Leave spare zones and spare current. A panel that is exactly full on day one is a problem on day two.
      • Walk-test with the customer. Arm the system, walk every route an intruder could take, and show them each zone tripping.
      • Leave a record set on site: the plan as built, the zone schedule, battery date and test results.

      Common mistakes

      • Starting from a kit of parts and fitting the building to it.
      • Protecting the front door well and forgetting the roll-up door, the skylight or the shared wall.
      • Relying on one layer: contacts only, or motion detectors only.
      • Placing the keypad where the cable was easy, not where people walk in.
      • Putting many devices on one zone to save money, so that an alarm cannot be located.
      • Handing over without a walk test and without training.

      Summary

      • Design starts with what is being protected, when the building is empty, and a walk round it.
      • Cover every opening in the perimeter, then put an interior layer behind it.
      • How people come and go decides entry routes, keypads and delays.
      • The zone schedule records every decision for every zone.
      • Leave room to grow, review for false alarms, walk-test everything and train every user.

      Exercises

      Answer each one yourself first, then open the answer. The plan at the top will help.

      Exercise 1. In the plan, switch on all ten devices. How many zones are used, and what does the panel need?

      Show answer
      Nine zones. Devices 1 to 9 each take a zone, and the second keypad takes none. Nine do not fit on an eight-zone panel, so it needs a zone expander.

      Exercise 2. Switch off devices 2 and 3 and leave the rest on. What can happen at the front of the store without the system noticing?

      Show answer
      Someone can break a display window, reach or climb in, and take stock from the shop floor. The front door contact never opens, and there is no glass-break detector or motion detector covering that room.

      Exercise 3. Write a zone schedule row for a new device: a contact on a roof hatch in the stockroom ceiling, 60 feet of cable from the panel. The hatch is used only by maintenance contractors, a few times a year.

      Show answer
      Name: Stockroom roof hatch. Device: surface contact suited to a metal hatch. Type: perimeter, instant. Wiring: wired, end-of-line resistor at the contact. Run: 60 feet. Because it is almost never opened, some designers make it a 24-hour zone so that it alarms even when the store is open. If so, contractors must be told to call before opening it.

      Exercise 4 (think, don't memorize). The customer's budget covers six zones of equipment, and you believe the store needs eight. What do you do?

      Show answer
      Show the customer the plan with the layers marked, and what each missing device would leave open. Then offer choices instead of quietly leaving gaps. Keep the whole perimeter and the hold-up button, and combine the two smaller motion detectors' rooms under one well-placed detector if the layout allows. Or install the panel and cable for all eight now and add the last two devices later, which is cheap. Or strengthen a weak opening physically, such as a bar on the roll-up door, so that it needs less detection. The decision is the customer's. Your job is to make sure they are choosing with the gaps in plain view, and to write down what was decided.

      After this course

      You have finished Intrusion Detection. The signal that leaves the panel is where the next course begins: Alarm Monitoring follows it to the monitoring center and on to the people who respond. Perimeter Protection takes detection outdoors, to the fence line. And Access Control and Video Surveillance show how the doors and cameras in the same building can work with the alarm system as one.