Intrusion Detection, lesson 11 of 12
False alarms
Most alarm signals are not burglaries. They are a late code, a drifting balloon or a door that rattles in the wind. Each one costs someone a wasted trip and teaches people to trust the system a little less. This lesson shows where false alarms come from and how to remove them at the design stage.
Ninety seconds at the front door
Pick a situation, then play or step through. Watch when the signal leaves the building, and what it says.
The everyday picture
You know the story of the boy who cried wolf. The villagers came running twice for nothing, and the third time they stayed home.
Car alarms went the same way. When one sounds in a parking lot, almost nobody looks up. The alarm works perfectly and protects nothing, because people have learned that it is nearly always a mistake.
A building alarm lives or dies by the same rule. Its real output is not noise. It is the belief, in the mind of a neighbor, an owner or a police dispatcher, that this signal is worth acting on. Every false alarm spends some of that belief.
Where false alarms come from
A false alarm is an alarm signal that brings a response when no crime or emergency was taking place. Police departments commonly report that well over nine in ten alarm calls turn out to be false. Many towns now require alarm permits and charge fines after the first few, and some will not send officers at all without confirmation.
The causes fall into three groups. The first is by far the largest.
- People A wrong or late code, a new employee who was never shown, a cleaner arriving off schedule, a door left ajar at closing, a pet left in an armed area.
- Design and installation The wrong sensor for the room, or the right sensor in the wrong place: a motion detector facing a heater, a contact on a door that rattles, a glass-break detector beside a noisy kitchen.
- Equipment and upkeep A weak battery after a power cut, a corroded connection, a wireless sensor that was never replaced, insects or dust inside a detector, damaged cable.
You met the physical causes in "Motion detectors" and "Glass-break, shock and vibration". The table gathers them with the design answer for each.
| Cause | Why it trips | Design answer |
|---|---|---|
| Heater, vent or sunlit window in a motion detector's view | Moving warm air or a fast change in temperature looks like a body | Aim the detector away, or use a dual-technology detector that needs heat and movement together |
| Balloons, banners, hanging signs, plants in a draft | They move when the heating comes on at night | Tell the customer. Use dual technology in retail and offices that decorate. |
| Pets | A warm body crossing the pattern | A pet-tolerant detector fitted exactly as its instructions say, or protect doors and windows only in those rooms |
| Loose or warped doors | Wind moves the door far enough to separate magnet and switch | Fix the door first. Then use a contact with a wider gap rating. |
| Roll-up doors | They flex and bounce | A heavy-duty floor-mounted contact made for overhead doors |
| Entry route too long for the delay | Staff cannot reach the keypad in time | Move the keypad nearer the door, or lengthen the delay within the limits allowed |
What the panel can do
In the United States, most control panels are built to a false-alarm reduction standard, ANSI/SIA CP-01. It sets out features that give people a chance to correct a mistake before it becomes a police call. The timeline at the top shows the most important ones working together. The times below are common defaults. Confirm them in the panel manual and against local rules.
| Feature | What it does |
|---|---|
| Abort window | After an alarm starts, the panel sounds the siren and waits a short time, commonly 30 seconds, before sending the signal. A valid code in that time stops the signal. |
| Cancel | If a code is entered after the signal has gone, the panel sends a second message saying an authorized user has canceled. |
| Swinger shutdown | A zone that trips again and again in one armed period is shut off after a set number of trips, commonly one or two, so a rattling door cannot send twenty alarms in a night. |
| Cross zoning | Two chosen zones must both trip within a set time before an alarm is declared. |
| Exit error | If the exit door is still open when exit delay ends, the panel sounds locally and gives the user a chance to fix it before reporting. |
| Exit time restart | If someone comes back in during exit delay, the delay starts again once, so they are not caught halfway. |
| Recent closing | An alarm within a couple of minutes of arming is reported with a note that the system was just armed, which usually points to a user mistake. |
Every one of these trades a little speed for a lot of certainty. Thirty seconds of abort window is thirty seconds in which a real signal does not go out. For most sites that is a good trade. For a few it is not, and the insurer or a standard may limit it. That is a design decision, to be made with the customer.
Swinger shutdown and cross zoning also need care. A zone that has been shut off no longer protects, so the cause must be found the next morning. Cross zoning only works if both zones can see the same intruder, and a failed detector in a cross-zoned pair can quietly disable both.
Check yourself
An owner trips the alarm and enters a valid code 50 seconds after the siren started. The abort window is 30 seconds. What reaches the monitoring center?
Verification
Verification means getting some second piece of evidence before asking the police to go. It happens after the signal leaves the building, and the Alarm Monitoring course covers it in depth. As a designer you decide what evidence the system can offer.
- Calling. The monitoring center phones the premises and then a second number, such as the owner's cell phone, before requesting dispatch. This simple step removes a large share of false calls.
- A second sensor. A door contact followed by a motion detector inside tells a story of someone moving through the building. Plan zones so that a real intruder trips more than one.
- Sound or pictures. Microphones, or cameras that send a short clip with the alarm, let an operator hear or see what tripped the sensor.
Audit a site
Use this before handing over any system, or when a customer calls about fines. Switch on what the site already has.
What is already in place?
Three examples
Simple: the birthday balloons
An office is armed on Friday evening. At 2 a.m. on Saturday the reception motion detector trips, and the police find nothing. On Monday there are helium balloons from a birthday party, now drifting near the ceiling vent.
There is nothing to repair. The fix is a line in the closing checklist, a word with the office manager, and a note on the account. If it keeps happening, a dual-technology detector in reception is the hardware answer.
Medium: the Monday morning alarm
A bakery has a false alarm most Monday mornings and almost none on other days. The alarm history shows the back door zone, a few seconds after entry delay ends. On Mondays the weekend baker opens up. Nobody gave him his own code, so he uses one written on a card and often gets it wrong the first time. The keypad is also at the front of the shop, 60 feet from the back door.
The installer adds a second keypad beside the back door, gives the baker his own code, and spends ten minutes practicing with him. The entry delay stays at 30 seconds. The alarms stop.
Advanced: a warehouse the police stopped attending
A distribution warehouse has had eleven false alarms in a year. The town has withdrawn police response until the system is fixed. The history shows three patterns: the dock door zones on windy nights, the motion detectors near the unit heaters on cold nights, and alarms just after closing.
The redesign takes each in turn. The dock doors get heavy-duty overhead-door contacts, and two that no longer close square are repaired. The motion detectors near the heaters are replaced with dual-technology units and aimed along the aisles. For closing, staff get a simple routine and the panel's exit error and recent closing features are turned on. Finally the dock contacts and the aisle detectors are arranged so that anyone coming through a dock door trips two zones, and the monitoring center is told to treat two zones as confirmed. After three clean months, the owner takes the records to the town and asks for response to be restored.
From the field
- Read the alarm history before touching anything. The zone, the day and the time usually point straight at the cause.
- Visit at the hour the alarm happens. Heating that starts at 4 a.m. cannot be seen at noon.
- Spend the last half hour of every job on training. Have each user arm, disarm and cancel an alarm themselves.
- Leave the cancel procedure and the monitoring center's number by the phone, not the codes.
- Walk-test every motion detector after furniture, racking or displays change.
- Treat the first false alarm as a service call. The second is easier to prevent than the fifth.
Common mistakes
- Turning a detector's sensitivity down until it stops false alarming, and no longer detects.
- Bypassing a troublesome zone for good instead of repairing it.
- Setting a very long entry delay to hide a badly placed keypad.
- Sharing one code among all staff, so mistakes cannot be traced or trained away.
- Relying on swinger shutdown and never asking why the zone tripped.
- Blaming the equipment before looking at how people use it.
Summary
- Most alarm signals are false, and most false alarms are caused by people, not parts.
- Choose and place each sensor for what the room does at night.
- The abort window, cancel, swinger shutdown and cross zoning give mistakes a chance to be corrected.
- Plan for a second piece of evidence: a phone call, a second zone, sound or pictures.
- Training and a closing routine prevent more false alarms than any device.
Exercises
Answer each one yourself first, then open the answer.
Exercise 1. In the timeline at the top, at what time does the signal leave the building if nobody enters a code, with a 30-second entry delay and a 30-second abort window?
Show answer
Exercise 2. What is the difference between an abort and a cancel?
Show answer
Exercise 3. A stockroom door zone trips four times on a stormy night. Swinger shutdown is set to two trips. How many alarm signals does the monitoring center receive from that zone, and what must happen the next day?
Show answer
Exercise 4 (think, don't memorize). A customer with a history of false alarms asks you to cross-zone every sensor in the building, "so it only goes off if two things trip". What do you say?