PanelSimulator Academy

Intrusion Detection, lesson 10 of 12

Panic, duress and hold-up

Every sensor so far has watched an empty building. These alarms are different: a person raises them, on purpose, while they are in danger. This lesson explains the three kinds, why some must be silent, and how to place the devices so that they work once and never by accident.

About 14 minutes. Read "Sounders, strobes and outputs" first.

One counter, four actions

Choose what the clerk does. Compare what the room notices with what the monitoring center receives.

in the shop siren Ready keypad hold-up button, under the counter Acct 4471 Corner Pharmacy Monitoring center Nothing unusual in the room
In the room
At the monitoring center

The everyday picture

A lifeguard has a whistle. One blast and every head on the beach turns, which is the point: the swimmer in trouble needs attention, fast, from everyone.

Now picture a bank teller with a note pushed across the counter. A whistle is the last thing they should use. What they need is a way to tell someone far away, without the person in front of them seeing any change at all.

Both are people calling for help. One call must be as loud as possible and the other must be invisible. Choosing between them, correctly, for each place and each threat, is most of this lesson.

Three kinds of alarm

The trade uses three words. They are often mixed up, and the differences matter to the people who respond.

  • A panic alarm is a general call for help that anyone on the premises can raise. In a home it is usually loud, because noise may drive off a prowler and bring the neighbors.
  • A hold-up alarm is raised during a robbery, usually in a business that handles cash or valuables. It is silent on site.
  • A duress alarm is raised by a person who is being forced to operate the system, for example to disarm it and open the door. They enter a special duress code at the keypad. The system does exactly what was asked and, at the same moment, silently reports that the user is under threat.
PanicHold-upDuress
Typical placeHomes, reception desks, lone workersBanks, pharmacies, jewelers, cash officesAnywhere someone opens or closes alone
Raised withKeypad keys, key fob, pendant, wall buttonHidden button, foot rail, money clipA special code at the keypad
On siteUsually sirensNothingNothing unusual. The system arms or disarms as normal.
Works when disarmedYesYesIt is part of arming and disarming

A signal from any of the three is treated as a person in danger, and it normally gets a faster and larger response than a burglary signal from an empty building. That is their value. It is also why a false one is costly, and why many towns fine for them.

The devices

A hold-up device has to satisfy two demands that pull against each other. It must be easy to operate without being seen, and almost impossible to operate by accident.

DeviceHow it is operatedGuard against accidents
Hold-up buttonPressed by hand, under a counter or deskTwo buttons that must be squeezed together, or a recessed button
Foot railLifted with the toe from underneath, at a teller positionLifting is not a movement feet make by chance. A cover stops cleaning equipment reaching it.
Money clipSits in the cash drawer under the last bills. Pulling those bills out triggers it.Staff are trained never to take the bait bills in normal work
Keypad panic keysTwo keys held together, or one key held for about two secondsThe hold time, and needing two keys
Key fob or pendantA button on a wireless transmitter carried by the personA recessed button, a hold time or a double press

Many hold-up buttons latch: once pressed they stay tripped, and often show a small flag or light, until someone resets them with a key. After an event there is no argument about which button was used. It also means the zone stays in alarm until the button is reset, so the reset key must be kept on site.

A fixed button tells responders exactly where the trouble is. A pendant goes with the person, so the panel knows who pressed it and not where they were standing. For staff who move around, that gap needs a plan, such as a rule about where to go, or cameras that the monitoring center can view.

Check yourself

A manager is forced to disarm the alarm at opening time and enters the duress code. What does the keypad do?

How the panel treats them

A wired hold-up button is a contact on a zone, like a door contact. The difference is the zone's type. In "Zones and partitions" you met zones that are active 24 hours a day, whether the system is armed or not. Panic and hold-up devices go on such zones, in one of two flavors:

  • 24-hour silent. No siren, no keypad message, no beep. The panel only sends its signal.
  • 24-hour audible. The sirens sound and the signal is sent.

Give every such device its own zone with a clear name, such as "Hold-up, pharmacy counter". The monitoring center passes that name to the police.

Duress is a code, not a zone. It is switched off in most panels until the installer turns it on. Make it a separate code that is easy to remember and unlike the user's own. A duress code that is the normal code with the last digit changed by one is a well-known source of false alarms, because a slip of the finger sends for the police. The false-alarm standard that United States panels are commonly built to discourages that kind of code for the same reason.

Before any of these go live, agree in writing with the monitoring center what happens on each signal: whether they call the premises first, what a person who answers must say to cancel, and what word means "I cannot speak freely". Practice differs between centers and between police departments, so do not assume.

Silent or audible?

The rule of thumb: if the threat is a person standing in front of the victim, stay silent. If noise and attention will help and will not provoke, be loud.

Six situations, your call

Decide how each alarm should behave on site, then read why.

Placing and running them

  • Reach. Sit or stand where the staff member works and find a spot the hand or foot reaches without leaning, looking down or moving the shoulders.
  • Clear of knees and bags. Under-counter buttons get struck by knees, chair arms, handbags and vacuum cleaners. Mount them away from where legs swing.
  • More than one position. Put a device at each till, and one in the back room or cash office where staff may be taken.
  • Out of the customer's sight line, including from the side and through any glass.
  • Training. People who have never pressed the button in a test tend not to press it when it counts. Train every new member of staff, and tell them when not to use it, such as for a shoplifter who has already left.
  • Testing. Test each device on a schedule agreed with the customer, often monthly, with the monitoring center put on test first. Confirm that the right zone name arrived.

Three examples

Simple: a panic button for a home

An older couple want a way to call for help at night. The installer enables the keypad's panic keys as audible and adds a wireless panic button on each bedside table, also audible. The sirens bring attention and the signal reaches the monitoring center. The couple practice once with the center on test, so they know how long to hold the button.

Medium: the knee that called the police

A convenience store has had three false hold-up alarms in two months, and the town has started to fine. Each one happened during a shift change. The single-press button is mounted on the underside of the counter, directly above where the clerk's stool slides in.

The installer replaces it with a two-button device that must be squeezed from both sides, moves it eight inches to the side of the knee space, and retrains the staff. The false alarms stop. Nothing about the panel was wrong.

Advanced: opening a jewelry store

The riskiest moment for a jeweler is opening up, when one person unlocks an empty store. The design uses three layers. Each keyholder has a duress code that is nothing like their own. A hold-up button sits inside the safe room, on a silent 24-hour zone named for that room. And the store follows an opening routine with the monitoring center: the system must be disarmed within an agreed time window, and the keyholder then gives an all-clear signal. If the all-clear does not arrive, the center follows the agreed plan.

No single device carries the whole burden. A person under threat has a quiet way to signal at the keypad, in the back room, and by doing nothing at all.

From the field

  • Check a silent zone twice in programming. One wrong setting makes a hold-up button sound the sirens, which is the worst possible fault.
  • After any change, test with the customer watching the keypad. A silent alarm must leave no trace on it that a robber could notice.
  • Leave the reset key for latching buttons in a known place, and show the manager how to use it.
  • Change wireless pendant batteries on a schedule, and make sure pendants are supervised like any other sensor.
  • Write the cancel procedure on a card for the manager, not on the wall by the keypad.

Common mistakes

  • Making a hold-up alarm audible.
  • Using a duress code one digit away from the normal code.
  • Mounting a single-press button where knees and bags hit it.
  • Putting several buttons on one zone, so nobody knows which position called.
  • Installing the devices and never training or testing.
  • Letting staff use the hold-up button for things that are not robberies.

Summary

  • Panic is a general call for help, hold-up is for robbery, and duress is a code entered by someone being forced.
  • If the threat is in the room, the alarm is silent on site.
  • These devices work around the clock, on 24-hour zones, whether or not the system is armed.
  • A good device is easy to use unseen and hard to trip by accident.
  • Placement, training, testing and an agreed plan with the monitoring center matter as much as the hardware.

Exercises

Answer each one yourself first, then open the answer.

Exercise 1. In the tool at the top, which two actions look identical in the room? What is different about them?

Show answer
The normal code and the duress code. The keypad and the system behave the same way. Only the signal differs: one is a routine opening and the other tells the monitoring center that the user is being forced.

Exercise 2. A shop is disarmed and open. Will its hold-up button work? Why?

Show answer
Yes. It is on a 24-hour zone, which is active whether the system is armed or disarmed.

Exercise 3. Give two ways a hold-up device is protected against being operated by accident.

Show answer
Any two of: two buttons that must be pressed together, a recessed button, a hold time, a foot rail that must be lifted, a cover, and mounting it away from knees, bags and cleaning equipment.

Exercise 4 (think, don't memorize). A clinic receptionist deals with angry visitors a few times a year, and the manager asks for "a panic button". What do you ask before choosing silent or audible?

Show answer
Ask what help is wanted and from whom. If the aim is for colleagues down the corridor to come at once, a signal that sounds or flashes in the staff area, away from reception, may serve better than a siren in the visitor's face or a silent call to police who are minutes away. Ask whether the visitor being able to hear it would calm or provoke. Ask who will respond and whether they have been told what to do. Many clinics end up with a discreet button that alerts staff nearby first, with a second, deliberate action to call the police. The device follows from the response plan, not the other way round.