PanelSimulator Academy

Intrusion Detection, lesson 9 of 12

Sounders, strobes and outputs

So far the course has been about noticing. This lesson is about what the panel does next, on site, in the first seconds. You will learn what each sounder and light is for, how the panel switches them, and how to work out whether the battery can carry them.

About 14 minutes. Read "Arming, disarming and entry delay" first.

Follow one alarm

Pick a situation, then play or step through. Watch which devices act, and for how long.

inside the shop street Armed Panel signal sent to monitoring Inside sounder Keypad Outside siren and strobe 11:42 p.m. Quiet

The everyday picture

Think of a smoke alarm in a kitchen and a lighthouse on a rock. The smoke alarm is for the people in the room: it says "something is wrong here, now". The lighthouse is for people far away: it says "this is the place".

An alarm system needs both jobs done. A sounder inside tells whoever is in the building. A siren outside tells the street. A flashing light on the wall tells a police officer or a guard, arriving at a row of identical shop fronts, which one to walk up to.

The things that make noise and light

The trade word for anything that announces an alarm is a notification device. Sounder, siren and bell are used loosely for the same thing. Older systems had real bells, and the terminals on a panel are still often marked "bell".

  • Inside sounder A small siren or speaker indoors. It makes staying in the building unpleasant and tells anyone inside that the alarm has tripped.
  • Outside siren A weatherproof box high on an outside wall, out of easy reach. It draws attention from the street and neighbors.
  • Strobe A flashing light, often built into the outside box. It marks the building, and it can keep flashing after the siren has timed out.
  • Keypad sounder The quiet beeper in the keypad. It counts down entry and exit delay and announces troubles. It is not meant to scare anyone.

Loudness is measured in decibels, written dB. Security sirens are commonly rated somewhere between 100 and 120 dB, measured close to the siren. That is loud enough to hurt at arm's length, and sound fades quickly with distance and through walls, so one siren does not fill a large building.

The sound itself carries meaning. Burglary sirens usually give a steady or warbling tone. Fire alarms in the United States use a pattern of three pulses and a pause, and carbon monoxide alarms use four. When one panel handles both burglary and fire, it must make the two sound different, so that people know whether to leave the building.

Kind of alarmInside sounderOutside sirenStrobeSignal to monitoring
BurglaryYesYes, until the cutoff timeYes, often until disarmedYes
Hold-up or duressNoNoNoYes
Tamper while disarmedOften keypad only. Set in programming.Usually noUsually noYes
Trouble, such as low batteryKeypad beep onlyNoNoYes, as a trouble

The siren output

The panel has a pair of terminals that switch 12 volts onto the siren circuit during an alarm. Three settings and limits matter.

  • Current. The output can deliver only so much, commonly 1 to 2 amps. A single siren can draw half an amp to more than an amp. If the sirens together need more than the output allows, the output drives a relay, and the relay switches a separate power supply.
  • Cutoff time. The siren cutoff, also called bell timeout, stops the siren after a set number of minutes. Many towns limit how long an outside siren may sound, often to somewhere between 5 and 15 minutes. Ask the local authority what applies, and program the panel to match.
  • Supervision. Many panels watch the siren circuit the way they watch a zone, and report a trouble if the wire is cut or the siren is removed. Some need a resistor across the terminals for this. The manual says which.

A stronger design for the outside box is a self-contained siren. It has a small battery of its own and a tamper switch. The panel normally holds it quiet. If the cable is cut or the cover is pried off, the box sounds from its own battery. Step through the third situation at the top to see it.

Check yourself

A burglary alarm has been sounding for longer than the siren cutoff time, and nobody has disarmed. What is still happening?

Programmable outputs

Besides the siren terminals, a panel has a few small outputs that you can assign to events. They are usually called programmable outputs, or PGMs. Think of each one as a tiny switch that the panel closes when something you chose happens.

These outputs are weak. Many can switch only about 50 milliamps, enough for an indicator light or the coil of a small relay, and many switch the negative side of the circuit instead of supplying 12 volts. To control anything larger, the output drives a relay and the relay's contacts do the work. Check the terminal's rating before connecting anything to it.

The output followsTypical use
Alarm, until disarmedA strobe that keeps flashing after the siren stops
Armed stateA light by the door showing staff the system is set, or a signal to the access control system
Any burglary alarmSwitching on lights, or telling a video recorder to mark the moment
Entry and exit delayA louder beeper in a noisy workshop, so people notice the countdown
A command from the keypadResetting a latched detector by dropping its power for a few seconds

One caution. An output that unlocks or opens something, such as a garage door, turns a convenience into a way in. Keep outputs to announcing and signaling unless you have thought through who can trigger them.

Size the battery

The panel's battery has two jobs in a power cut: keep the system running quietly for hours, then still have enough left to sound the sirens. The sum has three steps. Multiply the quiet load by the hours of standby. Add the alarm load multiplied by the minutes of sounding, as a fraction of an hour. Then add a quarter, because batteries weaken with age and cold.

Add up one panel

Starting figures are typical. Use the data sheet figures on a real job.

total siren current
amp-hours needed, with margin
smallest suitable battery

How many hours of standby you need depends on the kind of system and on the standard or insurer behind it. Four hours is a common figure for ordinary burglary systems, and some installations must last 24 hours or more. Confirm the requirement before choosing the battery.

Three examples

Simple: the siren nobody could hear

A house has one siren, and the installer put it in the attic to keep it out of sight. In a test, the owners can barely hear it in the bedrooms, and from the street it is a faint hum. The fix is to move it: an inside sounder in the central hallway, and an outside siren under the eave facing the road.

Medium: the output that kept resetting the panel

A workshop adds two large sirens to the panel's siren terminals. On the next alarm the panel restarts, again and again. Each siren draws 1.2 amps, a total of 2.4 amps, and the output is rated for 1.5. The panel's protection shuts the output down.

The cure is a relay and a small separate 12-volt supply with its own battery. The panel's output now only energizes the relay coil, a few tens of milliamps, and the supply carries the sirens.

Advanced: one building, four tenants

A small commercial building has four tenants, each with its own partition, as in "Zones and partitions". One shared outside siren would leave everyone guessing whose alarm it was, and one tenant's cutoff and disarm would silence another's.

The designer gives each tenant an inside sounder that follows only that partition. A strobe over each tenant's street door is driven by a programmable output that follows that partition's alarm until it is disarmed. One outside siren follows any partition, with a 10-minute cutoff agreed with the town. A responding officer hears the siren from the road and sees which door is flashing.

From the field

  • Mount the outside box high, where a ladder is needed, and bring the cable in through the wall directly behind it so that no cable is exposed.
  • Warn everyone, and the monitoring center, before testing sirens. Wear hearing protection when testing indoors.
  • Use heavier wire for sirens, typically 18 AWG, and keep runs short. Thin wire on a long run starves a siren and makes it quiet.
  • Watch polarity. Sirens and strobes are marked positive and negative, and many are silent if reversed.
  • Test on battery alone at the end of the job: unplug the transformer, trip an alarm, and listen.

Common mistakes

  • Loading the siren output beyond its rating.
  • Leaving the cutoff time at whatever the factory set, without checking the local rule.
  • Connecting a load straight to a programmable output that can only drive a relay.
  • Fitting only an inside sounder, so nobody outside ever knows.
  • Sizing the battery for the quiet hours and forgetting the sirens.

Summary

  • Inside sounders warn people in the building. Outside sirens and strobes tell the street which building.
  • The siren output has a current limit, a cutoff time and often supervision.
  • A self-contained outside siren sounds by itself if its cable is cut.
  • Programmable outputs are small switches tied to events, and they usually need a relay.
  • The battery must carry the quiet hours and the sirens, with a quarter to spare.

Exercises

Answer each one yourself first, then open the answer.

Exercise 1. Why does a hold-up alarm sound nothing on site?

Show answer
The person who caused it is standing in front of the staff. A siren could turn a robbery into violence. The signal goes quietly to the monitoring center. The next lesson covers this.

Exercise 2. A panel draws 300 milliamps when quiet. In alarm it draws 1.5 amps in total. It must stand by for 4 hours and then sound for 15 minutes. What battery capacity is needed, with a quarter added?

Show answer
Standby: 0.3 amps times 4 hours is 1.2 amp-hours. Alarm: 1.5 amps times a quarter of an hour is 0.375 amp-hours. Total 1.575, and with a quarter added, about 1.97 amp-hours. A 4 amp-hour battery is the usual small size that covers it.

Exercise 3. A programmable output is rated to switch 50 milliamps. The customer wants it to turn on a strobe that draws 200 milliamps. What do you do?

Show answer
Use the output to energize a small relay whose coil draws less than 50 milliamps, and let the relay's contacts switch the strobe from the auxiliary power terminals or a separate supply. Then check that the supply has 200 milliamps to spare.

Exercise 4 (think, don't memorize). A homeowner in a quiet street asks you to disable the siren cutoff "so it rings until I get home". What do you explain?

Show answer
After the first few minutes a siren has done its work: anyone inside has heard it, and the neighbors have noticed. Hours of noise add nothing, may break a local ordinance, drain the battery, and teach the neighbors to ignore the next alarm. Offer the things that do keep working: a strobe that flashes until the system is disarmed, the signal to the monitoring center, and the alarm memory on the keypad.