Intrusion Detection, lesson 7 of 12
Wiring and supervision
A sensor is only useful if the panel can hear it. This lesson follows the pair of wires between a sensor and the panel, and shows how one small resistor lets the panel tell a quiet night from a damaged cable. You will also learn to find a wiring fault with nothing more than a meter.
Watch one zone loop
Pick a way of wiring the zone, then step through four situations and compare what the panel can tell.
The everyday picture
Imagine a night watchman who cannot see the far end of a long corridor. He ties a string to the door down there and holds the other end. If the door opens, the string goes slack and he knows.
Two things can spoil this. The string could be cut, which at least feels like the door opening. Or it could snag on a nail halfway along. Then his end stays tight, and the door can open all night without him feeling a thing.
A careful watchman hangs a small weight on the far end and learns how it feels. Slack is wrong. Too tight is wrong. Only that one weight means "all is well". That weight is what an installer calls an end-of-line resistor.
What a zone loop is
Each zone on a panel has two screw terminals. Two wires leave them, travel to the sensor and come back as one circuit. The trade calls this circuit a loop. The panel pushes a tiny current round the loop all the time and measures how hard the loop resists it. Resistance is measured in ohms, written Ω.
You met normally closed contacts in "Door and window contacts". With the door shut the contact is a closed switch and current flows. Open the door and it stops. A broken wire also stops the current, so a cut fails loudly instead of silently.
The panel's ability to notice damage to its own wiring is called supervision. A plain loop has a little of it. The next section shows how to get more.
-
Zone terminalsOne terminal for the zone and one common.
-
The contactThe switch inside the sensor. A reed switch in a door contact, or a relay in a motion detector.
-
End-of-line resistorA part the size of a grain of rice that gives the loop a known resistance.
-
Tamper switchA switch under a device's cover that opens if the cover is lifted.
Three ways to wire a zone
Step through the diagram at the top for each method as you read. The four situations are the same every time: all quiet, the door opens, a wire is cut, and the two wires touch each other. Wires that touch are called a short circuit, or a short.
A plain loop
No resistor at all. The panel knows two states: current flowing, or not. An open door and a cut wire look the same, which is acceptable. The weakness is the short. If the two wires touch anywhere along the run, current flows through the touch point and the panel sees a healthy loop forever, whatever the door does. A staple driven through the cable can do this on installation day.
One end-of-line resistor
An end-of-line resistor, shortened to EOL, sits in the loop at the far end. The value is set by the panel maker. Values from 1,000 to 6,800 ohms are all in use, so read the installation manual. This lesson uses 2,200 ohms.
Now the panel has three readings to tell apart. About 2,200 ohms means normal. No current at all means the door is open or a wire is cut. Close to zero ohms means the wires are shorted, and the panel reports a trouble: a fault that needs service, shown at the keypad. The blind spot of the plain loop is gone.
The resistor only protects the wire between itself and the panel. Fitted at the panel terminals, it supervises about one inch of wire. It belongs at the last device on the loop.
Two resistors
The third method is called double end-of-line, or DEOL. One resistor sits in line with the loop as before. A second is wired across the contact. While the door is shut, the closed contact gives the current an easy path around the second resistor, so the panel reads 2,200 ohms. When the door opens, the current must go through both, and the panel reads 4,400.
An opening door no longer breaks the circuit, so a broken circuit can only mean damage. The panel reports it as a tamper at any hour, armed or not.
| What happens | Plain loop | One resistor | Two resistors |
|---|---|---|---|
| All quiet | 0 Ω, normal | 2,200 Ω, normal | 2,200 Ω, normal |
| Door opens | Open, alarm | Open, alarm | 4,400 Ω, alarm |
| Wire cut | Open, looks like the door | Open, looks like the door | Open, tamper |
| Wires shorted | 0 Ω, looks normal | 0 Ω, trouble | 0 Ω, tamper |
The table is for normally closed contacts, the usual choice for burglary sensors. Normally open devices are wired across the loop instead, so that closing the contact shorts it. The panel manual shows how to program each arrangement.
Check yourself
A zone has one 2,200 ohm resistor, fitted at the panel terminals instead of at the door. A staple shorts the cable halfway along. What does the panel show?
Tamper switches
Motion detectors, sirens, keypads and the panel cabinet each carry a tamper switch. On a double end-of-line zone, the switch goes in series with the loop, so lifting the cover reads as tamper. Otherwise, the tamper switches of several devices are chained together onto a zone of their own, active 24 hours a day. That costs a zone and does not say which device was opened, but it is far better than leaving the tamper terminals empty.
Read the meter
When a zone misbehaves, disconnect its two wires from the panel and measure across them with a multimeter set to ohms. Try it for a zone that should read 2,200 ohms with every door shut.
The meter shows...
Why 2,206 and not 2,200? Thin 22 AWG alarm wire has about 16 ohms per 1,000 feet. A sensor 150 feet from the panel is on 300 feet of wire, out and back, which adds about 5 ohms. Resistors are also allowed to be a few percent off their marked value, so panels accept a band of readings.
Cable and runs
Most alarm cable is 22 AWG with two or four conductors in one jacket. Count what the device needs.
| Device | Conductors | Why |
|---|---|---|
| Door or window contact | 2 | One loop. Many installers pull 4 and leave a spare pair. |
| Motion or glass-break detector | 4, or 6 with a separate tamper | Two for 12-volt power, two for the alarm loop, two for the tamper if it is not in the loop. |
| Keypad | 4 | Two for power, two for data. Long runs may need 18 AWG. Check the manual. |
| Siren | 2, heavier | Sirens draw far more current than sensors, so 18 AWG is usual. |
Two layouts are common. In a home run, each sensor has its own cable back to the panel and its own zone. It uses more cable, and the keypad names the exact door. In a daisy chain, one cable visits several contacts in series and they share a zone. That suits a row of windows in one room. The resistor still goes at the last contact in the chain.
Powered detectors take their 12 volts from the panel's auxiliary power terminals, which supply a limited current, often around half an amp. Add up the draw of every detector and keypad from the data sheets before adding one more.
Three examples
Simple: the resistor in the wrong place
An installer finishes a small house and twists every resistor onto the panel terminals, because that is quick and tidy. All zones read 2,200 ohms and the system passes its test. In practice every loop is a plain loop with a decoration at the panel.
The fix is to move each resistor out to its sensor. Contacts with a resistor built in make that easy.
Medium: the zone that will not arm
A stockroom zone shows "open" for a second or two, a few times a week, and the staff cannot arm. The door contact tests fine. A meter across the loop at the panel wanders between 2,300 and 9,000 ohms when the cable is flexed where it enters the door frame.
The cause is a splice made by twisting the wires and wrapping them in tape. It has corroded and is barely touching. Remade with a crimped or soldered connector, the loop reads a steady 2,205 ohms.
Advanced: a jewelry store wants to know more
A jeweler's insurer asks whether the system would notice interference with the wiring during opening hours, when the alarm is not armed. With one resistor per zone, a cut wire in the daytime shows only as an open zone, and staff see open zones all day.
The designer moves the showroom and safe-room zones to double end-of-line wiring, puts each detector's tamper switch in its loop, and sets the panel to sound and report tampers around the clock. A damaged cable at noon is now an event with its own name.
From the field
- Learn the color bands of your panel's resistor. A 2,200 ohm part is red, red, red.
- Meter every loop before landing it on the panel. Write the reading on the cable tag.
- Label both ends of every cable with the zone number and the place, before the ceiling tiles go back.
- Staple beside the conductors, never through the jacket, and use staples made for low-voltage cable.
- Keep alarm cable away from mains wiring, and follow the electrical code for separation.
Common mistakes
- Fitting end-of-line resistors at the panel instead of at the last device.
- Using a resistor of the wrong value because it was the one in the van.
- Leaving tamper terminals unconnected.
- Chaining a whole floor onto one zone, so that a fault could be at any of twelve windows.
- Adding detectors without adding up the auxiliary power they draw.
Summary
- A zone is a loop of wire whose resistance the panel measures all the time.
- A plain closed loop notices a cut and is blind to a short.
- One end-of-line resistor, at the far end, lets the panel see a short as a trouble.
- Two resistors let the panel tell an open door from a cut wire, day and night.
- Tamper switches need to be wired somewhere, or they do nothing.
- A meter across the loop at the panel usually names the fault.
Exercises
Answer each one yourself first, then open the answer.
Exercise 1. On a zone with one 2,200 ohm end-of-line resistor and a normally closed contact, what does the panel read when the door is shut, and when it is open?
Show answer
Exercise 2. A sensor is 250 feet from the panel on 22 AWG cable. Roughly how much resistance does the cable add to the loop?
Show answer
Exercise 3. A zone that should read 2,200 ohms reads 1,100. Name the most likely cause.
Show answer
Exercise 4 (think, don't memorize). A customer asks why you want to charge more for double end-of-line wiring in a small accounting office that is armed every night and empty all weekend. What do you say?