Intrusion Detection, lesson 6 of 12
Arming, disarming and entry delay
Lesson 5 gave each zone a behavior and each area its own arming. Now people have to live with it. Most alarm signals are not caused by burglars. They are caused by the people who own the system, on the way in or out. This lesson covers the timers and habits that decide whether a system is used every night or switched off in frustration.
Follow the clock
Pick a situation, then play or step through it. The marker shows where you are in time.
The everyday picture
A modern car does not lock the instant you press the button and walk away, then trap your coat in the door. It gives you a moment. It flashes its lights so you know it locked. If a door is ajar it refuses and beeps at you. When you come back, it unlocks as you reach for the handle. None of this makes the car less secure. It makes the lock usable, so you lock the car every time.
An alarm system needs the same manners. It has to give people time to leave, time to come in, clear signals about what it is doing, and a way to undo an honest mistake.
Ways to arm and disarm
| Method | How it works | Strengths | Watch for |
|---|---|---|---|
| Keypad code | The user types a personal code of four to six digits | Nothing to carry. Each person has a separate code, so the log shows who. | Shared codes, and codes written beside the keypad |
| Fob or card | A button on a key ring, or a tag held to the keypad | Fast, and good for people who forget numbers | A lost fob works for whoever finds it until it is deleted |
| Phone app | The user arms or disarms through the maker's online service | Check and arm from anywhere. Alerts when the building is left unarmed. | Depends on the internet link and on a well-protected account |
| Schedule | The panel arms itself at a set time after a warning tone | A building is never left open by forgetfulness | Someone working late needs a way to postpone it |
| Access control link | A valid card at the door reader disarms the area, as covered in the Access Control course | One action unlocks and disarms | The two systems must agree on who is allowed |
Whatever the method, the panel will not arm over an open zone. The keypad shows "Not ready" and names the zone. The user closes the door or window, or bypasses that zone on purpose, as lesson 5 described.
The timers
Four timers shape every coming and going.
| Timer | Starts when | What it allows | Common setting |
|---|---|---|---|
| Exit delay | The user arms | Time to walk out through the entry and exit door. That door, and follower zones on the way, are ignored until it ends. | 60 seconds |
| Entry delay | An entry and exit zone opens while armed | Time to reach the keypad and disarm | 30 seconds |
| Abort window | A burglary alarm begins | The sounder runs, but the panel holds the signal briefly. A code in that time stops it from being sent. | 30 seconds |
| Sounder time | The sounder starts | How long it runs before it stops by itself | A few minutes, often limited by local noise rules |
The settings shown are the usual defaults on panels built to ANSI/SIA CP-01, a United States standard for features that reduce false alarms. Many cities and monitoring companies expect panels that meet it. Check the panel's manual for its allowed ranges and the local alarm ordinance for any limits.
The keypad makes each timer audible. During the exit delay it beeps slowly, then quickly for the last ten seconds. During the entry delay it sounds a steady tone that is hard to ignore. These sounds are the system talking to its users. Never turn them off to please a customer who finds them annoying. Turn them down if you must.
Check yourself
The entry delay ran out and the sounder started. Ten seconds later the owner enters a valid code. The abort window is 30 seconds. What does the monitoring center receive?
Set an entry delay
An entry delay should be long enough for the slowest honest user and no longer, because an intruder gets the same time. Measure the walk and let the numbers decide.
Entry delay calculator
"Seconds at the door" covers taking the key out, pushing the door shut and putting things down. The walking speeds are planning figures: about 4 feet a second for a brisk adult, 3 when loaded, 2 for someone slow. Time a real user if you can.
Features that forgive mistakes
People make the same few mistakes over and over, and panels have a matching set of answers. Names vary by maker.
- Exit time restart. Someone arms, steps out, then dashes back in for a forgotten phone. The panel sees the door open a second time during the exit delay and starts the delay again, once.
- Exit error. If the entry door is still open when the exit delay ends, the panel sounds at once and starts the entry delay. Whoever is still nearby hears it and comes back. If nobody disarms, the alarm is sent with a note that it began as an exit error.
- Automatic stay. The user arms in away mode but no door opens during the exit delay. The panel concludes that the user is still inside and arms in stay mode, so the motion detectors do not catch them.
- Recent closing. An alarm in the first couple of minutes after arming is flagged, because it is almost always the person who just left.
- Cancel. If a code is entered after the alarm has already been sent, the panel sends a second message saying an authorized user has cancelled. The monitoring center then follows its own procedure, which may still include a phone call.
These features do not weaken the system against a real intruder, who has no code. They only stop honest errors from becoming police calls. Lesson 11, False alarms, returns to why that matters so much.
Codes and records
- One code per person. When each user has a separate code, the log reads "disarmed by Maria, 6:52 a.m." and a leaver can be removed without changing everyone else's code.
- Levels. A master code can add and remove users. Ordinary codes arm and disarm. Some panels offer an arm-only code for cleaners and a temporary code that expires.
- Installer code. A separate code opens programming. Change it from the factory default on every job and record it securely.
- Openings and closings. Each disarm and arm can be reported to the monitoring center as an opening or a closing. With a schedule on file, the center can call when a shop has not closed by its usual time or is opened at 3 a.m.
- Duress. A special code disarms normally while sending a silent call for help. Lesson 10 covers it.
Three examples
Simple: a keypad by the door
A house has its keypad on the wall 6 feet inside the front door. The owner unlocks, steps in, closes the door and types a code. At 3 feet a second the walk takes 2 seconds, the door about 6 and the code about 6, for 14 seconds in all. With margin that is 21, so the standard 30-second entry delay is ample. The exit delay stays at 60 seconds.
Medium: the garage entry
A family comes home through the garage. The door from the garage to the kitchen has the contact, but the only keypad is by the front door, 45 feet away through the kitchen and hall. Loaded with shopping they walk at about 3 feet a second, which is 15 seconds, plus 6 at the door and 6 for the code: 27 seconds. The 30-second delay left them almost nothing, and they set off the alarm roughly once a month.
There were two possible fixes. Lengthening the delay to 45 seconds would work. The installer chose the better one and added a second keypad just inside the kitchen door, which cut the time needed to about 14 seconds and let the delay stay at 30. Fobs for the two drivers were added as well.
Advanced: a shop with twelve staff
A retail shop had one shared code, a rear door that did not always latch, and three or four false dispatches a year, each with a fine from the city. Nobody could say who had armed or disarmed on any night.
The redesign changed habits as much as hardware. Each keyholder received a personal code and the two managers a master code. The rear door closer was repaired, since half the alarms were exit errors from that door. Opening and closing reports were switched on with a schedule: if the shop is not armed by 9:30 p.m. the monitoring center phones the manager. The panel's exit error, abort window and cancel features were confirmed to be enabled, and every keyholder was shown what the keypad sounds mean and how to cancel. The following year the shop had no dispatches.
From the field
- Time the real walk with the real user, including the slowest person who has a code.
- Put the keypad where it can be heard from the door. A beep nobody hears reminds nobody.
- Train every user, not only the owner. Ten minutes at handover covering arm, disarm, bypass and cancel saves years of calls.
- Watch the door close. A door that does not latch by itself will cause exit errors whatever the settings.
- Make sure everyone knows the passphrase the monitoring center asks for when it calls. A flustered wrong answer becomes a dispatch.
Common mistakes
- Stretching the entry delay to several minutes instead of moving or adding a keypad.
- Silencing the exit and entry tones.
- One code shared by everyone, never changed when people leave.
- Leaving the installer code at its factory default.
- Switching off the abort window because "it delays the police", then paying for the false dispatches it would have prevented.
- Mounting the keypad where it can be seen and reached from outside through a window.
Summary
- Most alarm signals come from users. Design the routine so it is hard to get wrong.
- Exit delay lets people out. Entry delay lets them reach the keypad. Both are announced by sound.
- Set the entry delay from the measured walk, with margin. Add a keypad before adding minutes.
- Exit error, abort window and cancel stop honest mistakes from reaching the police.
- One code per person, and opening and closing reports, show who did what and when.
Exercises
Answer each one yourself first, then open the answer.
Exercise 1. What is the difference between the entry delay and the abort window?
Show answer
Exercise 2. The keypad is 60 feet from the entry door. A user carrying boxes walks at 3 feet a second, needs 6 seconds at the door and 6 for the code. What entry delay does the lesson's method suggest?
Show answer
Exercise 3. A user arms in away mode and then sits down to finish an email. Nobody opens a door. With automatic stay enabled, what state is the system in when the exit delay ends?
Show answer
Exercise 4 (think, don't memorize). An owner says, "Take off the entry delay. I want the alarm to go the second that door opens." What do you explain, and what could you offer?