Intrusion Detection, lesson 5 of 12
Zones and partitions
Lessons 2 to 4 covered the sensors. Sensors are only useful once the panel knows what each one is and how to treat it. Zones give every sensor a name and a behavior. Partitions split one panel into several areas that arm and disarm separately. Get these two right on paper and programming the panel becomes simple copying.
Arm part of a building
One panel protects an office and a warehouse that share a lobby. Arm or disarm each side, then select a numbered sensor to trip it.
The everyday picture
A school caretaker carries a ring of keys, and each key has a tag: "Gym, side door", "Science lab", "Boiler room, keep locked". The tag does two jobs. It says where the key belongs, and it reminds him of the rule for that door. Without tags he would have forty identical keys.
At night he locks the classroom wing but leaves the sports hall open for an evening club. The building is one building, yet it is closed in parts.
Zones are the tags. Partitions are the wings.
What a zone is
In lesson 1 a zone was the place where one sensor circuit lands on the panel. In full, a zone is three things together: a numbered input, a name a person can understand, and a programmed behavior. The panel reports by zone, the keypad displays by zone, and the monitoring center dispatches by zone.
The more exactly a zone points at one place, the more useful it is. "Zone 7, dock door" sends a guard to the dock. "Zone 3, warehouse" sends him to search 20,000 square feet. The working rule is one sensor per zone. Group sensors only when they are the same kind, in the same room, and nobody would act differently knowing which one tripped, such as three windows in one office.
Small panels have about eight zone inputs on the main board. Add-on modules called zone expanders, wired or wireless, take that to dozens or hundreds. Count your sensors before choosing the panel, and leave spare capacity.
Zone types
The behavior of a zone is chosen from a short menu. Makers use different names and numbers for the entries, but the menu is nearly the same everywhere.
| Zone type | Used for | When armed | In stay mode |
|---|---|---|---|
| Entry and exit | Doors people use to come and go | Starts the entry delay. Ignored during the exit delay. | Active |
| Perimeter, instant | Other outside doors, windows, glass-break and shock sensors | Alarms at once | Active |
| Interior follower | Motion detectors on the path between the entry door and the keypad | Alarms at once, unless an entry delay is already running, in which case it waits too | Ignored |
| Interior, instant | Other motion detectors and inside doors | Alarms at once | Ignored |
| 24-hour | Panic buttons, tamper switches, safes, freezers and other things that matter around the clock | Alarms in every state | Alarms in every state |
| Fire | Smoke and heat detectors, where the panel is listed for them | Alarms in every state with a different sounder pattern | The same |
The follower type solves a real problem. The keypad is rarely right at the door, and a motion detector usually sees the path to it. If that detector alarmed at once, every honest entry would be an alarm. As a follower, it stays quiet while the entry delay runs and alarms instantly if someone appears without the door having opened first, for example through a window.
A 24-hour zone can be audible or silent. A freezer temperature alarm might only beep at the keypad and report to the monitoring center. Lesson 10, Panic, duress and hold-up, deals with the silent kind.
Check yourself
A hallway motion detector looks at the route from the front door to the keypad. Which zone type lets the owner walk to the keypad, yet alarms at once on someone who climbed in through a window?
Give each sensor a type
Six sensors in a small shop. Choose the type you would program for each.
Which zone type?
Bypass, chime and the zone list
Two everyday features work zone by zone.
- Bypass tells the panel to leave one zone out for this arming period only. A user might bypass a window with a broken latch until it is repaired. The panel arms everything else, records who bypassed what, and can report it. A bypassed zone is a hole in the protection, so bypassing should need a code, and 24-hour and fire zones should not be bypassable by ordinary users.
- Chime makes the keypad sound a tone when a chosen zone opens while the system is disarmed. A shop uses it on the front door to hear customers arrive.
Before any programming, write a zone list. It is the single most useful document an alarm system has.
| Zone | Name | Sensor | Type | Partition |
|---|---|---|---|---|
| 1 | Front door | Recessed contact | Entry and exit | Lobby (common) |
| 2 | Lobby motion | PIR | Interior follower | Lobby (common) |
| 4 | Office window, north | Surface contact | Perimeter, instant | Office |
| 7 | Dock door | Overhead-door contact | Perimeter, instant | Warehouse |
| 9 | Reception panic button | Hold-up button | 24-hour | Office |
The names in the second column are what the keypad shows and what the monitoring center reads to the police. Write them for a stranger arriving in the dark: say which door, which side of the building, which floor.
Partitions
A partition, called an area by some makers, is a group of zones that arms and disarms together, separately from the rest. One panel, one battery and one communicator behave as two or more independent alarm systems. Small panels commonly offer two to eight partitions.
Each partition has its own:
- Zones. Every zone belongs to one partition.
- Users. A code can be valid in one partition, several or all. The warehouse supervisor cannot disarm the office.
- Keypads. A keypad is assigned to a partition and shows only that partition's zones, though a manager may be allowed to view others from it.
- Delays and reports. Entry time, exit time and the account details sent to the monitoring center can differ.
Space that several partitions share, such as a lobby or corridor, is set up as a common area. It follows a simple rule: it arms itself when the last of its partitions arms, and disarms when the first one disarms. Nobody has to remember the lobby. Try it in the plan at the top by arming both sides.
Partitions are for parts of a building with different people or different hours: a shop and its stock room, a doctor's office and its drug cupboard, a house and a rented apartment over the garage. They are not a substitute for stay mode, which already separates perimeter from interior within one partition. And where tenants are truly separate businesses, think hard before putting them on one panel. They would share one cabinet, one battery and one company's service visits, and a fault in one affects all.
Three examples
Simple: a house in eight zones
A single-story house has a front door, a door from the garage, a patio door, six windows that open, a hallway and a living room. The zone list reads: front door and garage door as entry and exit zones, the patio door as perimeter, the windows grouped by room into three perimeter zones, a follower motion detector in the hallway where the keypad hangs, and an instant motion detector in the living room. That makes eight zones on one partition, which fills a basic panel exactly, so the installer adds an expander to leave room for the smoke detectors the owner mentions.
Medium: the server room that was open all day
An office armed its alarm at night and disarmed it each morning. The server room had a door contact and a motion detector, but on the single partition they were disarmed all day along with the desks. Anyone in the building could walk in unnoticed for ten hours a day.
The fix was a second partition holding only the server room's two zones, with its own small keypad outside the door and codes for the three IT staff. It stays armed around the clock and is disarmed only for the minutes someone is working inside. Nothing was added except a keypad and an hour of programming.
Advanced: two tenants and a shared lobby
The building in the plan at the top has an office that works 8 to 6 and a warehouse that starts at 5 a.m. Both enter through one lobby. The owner wanted one system and one monitoring contract.
The design uses three partitions: office, warehouse, and the lobby as a common area. Each tenant has a keypad just inside its own door from the lobby, and a third keypad sits by the street door. When the warehouse crew arrives at 5, the first valid code disarms the warehouse and, with it, the lobby. The office stays fully armed. The reception panic button is a 24-hour zone, live at all hours. In the evening the last partition to arm takes the lobby with it. Each tenant's opening and closing reports go to the monitoring center separately, so a missed closing is noticed for the right business.
From the field
- Walk the building with the zone list in your hand and trip every sensor. Check that the keypad shows the name you expect. Swapped zones are common and only this test finds them.
- Tape a printed zone list inside the cabinet door and give the customer a copy. Update both when anything changes.
- Number zones in walking order around the building where you can. People find zone 6 faster when it sits between 5 and 7.
- Leave at least a fifth of the zones spare. Customers always add a door.
- Send the same names to the monitoring center that the keypad shows. Two descriptions for one zone cause confusion during an alarm.
Common mistakes
- Lumping many sensors into one zone to save inputs, then being unable to find a fault or direct a response.
- Making the hallway motion detector instant, so every entry alarms, or making every motion detector a follower, so none is instant.
- Leaving a zone bypassed for months after a quick fix.
- Letting every user's code work in every partition.
- Forgetting the shared corridor, so it belongs to no partition and is never armed.
- Naming zones by number or by cable color instead of by place.
Summary
- A zone is a numbered input with a name and a behavior. Aim for one sensor per zone.
- Zone types decide the response: delay, instant, follower, 24-hour or fire.
- Bypass leaves one zone out for one arming period, and should be recorded.
- A partition is a group of zones with its own users, keypads and arming state.
- A common area arms with the last partition and disarms with the first.
Exercises
Answer each one yourself first, then open the answer.
Exercise 1. What three things make up a zone?
Show answer
Exercise 2. In the plan at the top, the office is armed and the warehouse is disarmed. Is the lobby armed? What happens when the front door opens?
Show answer
Exercise 3. A shop has 2 outside doors, 5 opening windows in two rooms, 3 motion detectors, 1 glass-break detector and 2 panic buttons. Windows are grouped by room. How many zones is that, and what panel size would you choose from 8, 16 or 32?
Show answer
Exercise 4 (think, don't memorize). A homeowner asks for a partition for the upstairs bedrooms so the family can arm downstairs at night. Is a partition the right tool?