PanelSimulator Academy

Intercom and Visitor Management, lesson 8 of 8

Designing an entrance

An entrance is a few square feet where a reader, an intercom, a camera, a light and a door all have to work together, for staff in a hurry and for strangers who have never been there. This lesson puts the course together. You will place each device where it works, and learn to spot the layouts that fail before the wall is drilled.

About 14 minutes. Read the rest of this course first.

Lay out an entrance

An entrance seen from above. The door swings outward. Move the station and switch devices on and off.

insideoutside Lobby door open reader Overview camera Station Visitor

    The everyday picture

    Think of a front porch that works. There is a light, so you can be seen. The doorbell is where your hand expects it, beside the handle. There is room to stand without being hit by the door. From inside, the peephole shows your face and not the top of your hat.

    Now think of a porch that does not. The bell is hidden behind a plant. The light is behind you. The door opens toward you and you have to step back off the step. Every part is present, and the porch still fails.

    Entrance design is porch design. The parts are covered in the earlier lessons. This lesson is about where they go.

    Walk the approach

    Begin every design outside, forty feet away, as a stranger. Walk in and ask five questions in order.

    1. Can I tell which door is the entrance? A sign and a light answer this before any electronics do.
    2. Can I see what to press? The station should be the obvious thing beside the door, with a lit button.
    3. Where do I stand? In front of the station, on level ground, clear of the door's swing.
    4. Can they see and hear me? Face lit from the front, traffic noise allowed for, camera at a height that finds faces.
    5. When the door releases, can I reach it in time? The handle should be two or three steps from where I stand.

    Then walk it again as a member of staff with a card and a coffee, as a courier with a hand truck, and as a wheelchair user. Each walk finds a different fault.

    Where each device goes

    DevicePlace itBecause
    Door stationOn the latch side, a foot or two from the door edge, button no higher than 48 inches, with a clear level space about 30 by 48 inches in frontThe visitor ends the call already facing the handle, outside the door's swing
    Card readerLatch side, between the station and the door, at about 42 to 48 inchesStaff badge and pull in one movement
    Overview cameraHigh on the wall or soffit, to one side, looking across the approachIt shows who else is standing there, and it keeps recording after the call ends
    LightAbove or beside the door, shining on the visitor's faceThe station's camera needs light from the front, not from behind
    Door hardwareCloser, electric lock, door position switch and exit device, as in the Access Control courseA door that does not close and latch by itself undoes everything else
    SignAt eye level beside the station: who to call, and opening hoursA stranger should never have to guess

    The side of the door matters more than any other choice. The latch side is the edge with the handle. The hinge side is the other edge. On an outward-swinging door, a visitor at the hinge side is hidden behind the open door and must walk around it. Use the tool at the top to see both.

    The two cameras do different jobs. The station's camera sees one face at arm's length. The overview camera sees the scene: a second person waiting to follow the first through, a vehicle, a parcel left behind. An operator who sees both makes better decisions, and the recording is far more useful afterward.

    Check yourself

    An entrance door swings outward. Where should the door station go?

    One entrance, four kinds of arrival

    A design is complete when you can say, for each kind of person, what they do and what happens next.

    Who arrivesWhat they useWhat happens next
    Staff and residentsCard readerDoor releases in about a second. The controller records the entry.
    VisitorsDoor stationAn operator or host answers, identifies and releases. Sign-in and badge follow inside.
    DeliveriesDoor station, or a limited codeAdmitted to a vestibule or receiving point only
    Emergency respondersThe fire department's key box or other approved meansEntry without waiting for anyone to answer

    Add two more columns in your notes: what happens after hours, and what happens when power or the network fails. Lesson 3 gave you the questions. If any cell in that table is blank, the design is not finished.

    The inner door in the tool is the vestibule from lesson 5. Schools call the same idea a secure vestibule: a visitor is released into a small space, speaks to the office through a window, signs in, and only then is released through the second door. It turns one decision into two, with a face-to-face check between them.

    Vehicle gates

    A vehicle entrance follows the same rules with different numbers.

    • Driver's side. The station goes on the left of the lane, on a curved post called a gooseneck, close enough to reach through an open window.
    • Two heights for mixed traffic. A car driver's window and a truck driver's window are far apart. Sites with both commonly fit two stations on one post, a low one for cars and a high one for trucks. Posts are sold in standard heights for each. Measure the vehicles that use the site.
    • Set back from the gate. The vehicle must stop clear of the gate's travel, and there should be room for it to wait off the public road. A truck is 70 feet long.
    • Protection. A steel bollard in front of the post saves the station from the first careless bumper.
    • Distance. Gates are often beyond the 328-foot limit of copper network cable. Plan fiber or an extender from the start, with power at the gate.

    Gate operators have their own safety devices and standards, covered in Gates, turnstiles and elevators in the Access Control course. The intercom only asks the operator to open. It must not bypass the gate's safety sensors.

    Start a design

    Pick a kind of entrance to see a starting device list and the first thing to settle.

    What kind of entrance is it?

      Settle first

      Three examples

      Simple: the station on the wrong side

      An accounting office has its door station on the hinge side, because that wall already had a cable. Visitors press, the door releases, and by the time they have walked around the opening door the five seconds are up. The receptionist releases it two or three times per visitor. The station is moved four feet to the latch side, and the old hole is covered with a blank plate. The complaints stop the same day.

      Medium: the school entrance

      An elementary school keeps its main doors locked during the day. Visitors used to be released straight into a corridor, where the office could not see them.

      The new layout forms a vestibule from the existing second set of doors. The outer door has a video station and an overview camera. The office releases the visitor into the vestibule, where a window opens onto the office counter. The visitor signs in there and receives a badge, as in lesson 6. Only then does the office release the inner door. Staff use card readers on both doors. Both doors keep their exit hardware, so leaving is always one motion, and the fire marshal reviews the plan before work starts.

      Advanced: the distribution center gate

      A distribution center takes cars by day and trucks around the clock through one gate, 600 feet from the building. The guard booth is staffed only on weekdays.

      The design uses a gooseneck post with two IP video stations, low and high, behind a bollard, set back so a full-length truck can wait off the road. Fiber runs to a small heated cabinet at the gate, which holds a switch and power. An overview camera looks along the lane to read the truck and its plate. Staff use a long-range reader. Calls ring the guard booth by day and roll over to the shipping office at night, then to a monitoring service. The fire department's approved key switch opens the gate without any call. Each cell of the arrival table is filled, including the row for a network failure: the stations still ring the booth over the local switch, and the gate can be opened from there by a wired button.

      From the field

      • Tape paper cut-outs of each device to the wall and have the customer walk up to them before any hole is drilled.
      • Visit at night and in the late afternoon. Light and glare are invisible on a noon survey.
      • Check what is inside the wall at the chosen spot: glass, steel, stone or a structural column all change the mounting and the price.
      • Pull a spare cable to the entrance. The second visit to add a device costs far more than the cable.
      • Watch real people use the finished entrance for half an hour. Where they hesitate, something needs a sign or a move.

      Common mistakes

      • Putting devices where the cable was easy instead of where people stand.
      • Mounting the station on the hinge side or inside the door's swing.
      • Relying on the station's own camera as the only camera at the entrance.
      • Lighting the entrance from behind the visitor.
      • Designing for daytime only, with no plan for after hours or for a failure.

      Summary

      • Design from the visitor's side: find the door, find the button, stand, be seen, reach the handle.
      • Station and reader go on the latch side, within reach, clear of the swing.
      • A second, wider camera and front lighting make the operator's decision a good one.
      • Say what each kind of arrival does, by day, after hours and in a failure.
      • A vestibule turns one release into two checks. The way out never changes.

      Exercises

      Answer each one yourself first, then open the answer.

      Exercise 1. Why is the latch side the right place for a door station?

      Show answer
      The visitor finishes the call standing next to the handle, clear of the door's swing, and can pull the door within the release time. On the hinge side the open door stands between the visitor and the opening.

      Exercise 2. What does an overview camera add that the door station's camera cannot?

      Show answer
      A wide view of the whole approach: other people waiting to follow the visitor in, vehicles, and what happens after the call ends. It usually records continuously, while the station's camera shows one face during a call.

      Exercise 3. In the tool at the top, set the station on the latch side and switch on every device. Then switch off the card reader. What does the tool warn about, and why?

      Show answer
      Without a reader, staff must use the intercom. The operator releases the door for familiar voices all day, stops checking the picture, and no record is kept of which staff member entered. Lesson 1 described this habit.

      Exercise 4 (think, don't memorize). A clinic's entrance is a glass door set in a glass wall. There is no solid wall on the latch side for a station. What are your options?

      Show answer
      Put the station on a free-standing post or bollard on the latch side, fed by a conduit under the paving. Or use a narrow station made to mount on a door frame or mullion, if the frame is wide enough and the maker allows it. Or mount it on the nearest solid return wall with an angled wedge so that it faces where the visitor stands. In each case keep the button within reach, the space in front clear and level, and the visitor outside the door's swing. Do not solve it by moving to the hinge side because a wall happens to be there.