Electricity and Low Voltage, lesson 1 of 12
Voltage, current and resistance
Every reader, camera, sensor and lock is an electrical circuit. Three ideas describe all of them: voltage, current and resistance. Once you can picture those three, the labels on equipment and the faults you meet on site start to make sense.
Push, squeeze and flow
Raise the water level or squeeze the pipe, and watch the flow change. The small circuit above does the same thing with electricity.
The everyday picture
Picture a water tank on a roof with a pipe running down to a garden tap. The higher the water stands in the tank, the harder it pushes at the tap. That push is there whether the tap is open or shut.
Open the tap and water flows. How much flows depends on two things: how hard the tank pushes, and how narrow the pipe is. A wide pipe lets plenty through. A pipe pinched half shut lets through a trickle, even with a full tank.
Electricity behaves the same way. Something pushes, something flows, and something gets in the way. Those three things have names, and each has a unit that you will read on every label for the rest of your working life.
The three ideas
- Voltage The push. It is measured in volts, written V. A power supply creates it. Like the water level in the tank, it is present even when nothing is flowing.
- Current The flow. It is measured in amperes, shortened to amps and written A. Small devices are rated in milliamps, written mA. One amp is 1,000 milliamps.
- Resistance The narrowness. It is measured in ohms, written with the Greek letter Ω. Every device and every length of wire has some. More resistance means less flow for the same push.
The proper names are voltage, current and resistance. The table sets them beside the water picture.
| Idea | Unit | In the water picture | Where you read it on site |
|---|---|---|---|
| Voltage | Volt (V) | Height of water in the tank | The output of a power supply. The input a device asks for. |
| Current | Amp (A) or milliamp (mA) | Gallons per minute through the pipe | What a device draws. The most a supply can deliver. |
| Resistance | Ohm (Ω) | How narrow the pipe is | Cable tables, in ohms per 1,000 feet. Resistors used on alarm loops. |
Check yourself
You keep the water level the same and squeeze the pipe narrower. In electrical terms, what have you done, and what happens?
How they behave together
Current needs a complete loop
Water can pour out of a pipe onto the ground. Electricity cannot. Current flows only around a complete loop: out of the supply on one wire, through the device, and back to the supply on a second wire. That loop is a circuit. This is why almost everything you install has at least two power wires, usually marked + and −.
Break the loop anywhere and the current stops everywhere. A loose screw terminal, a broken wire inside a door hinge and an open switch all do the same thing. A broken loop is called an open circuit.
Voltage is always between two points
A water level only means something compared with the tap below it. In the same way, a voltage is always measured between two points. "12 volts" on a power supply means 12 volts between its + terminal and its − terminal. This is why a meter has two probes.
A device draws current. A supply does not push it in.
This surprises most newcomers. A power supply marked "12 V, 5 A" does not force 5 amps into anything. It holds 12 volts across its terminals and is able to deliver up to 5 amps. A reader that needs 0.15 amps takes 0.15 amps and no more, in the same way that a small tap on a large water main takes only what its opening allows.
So the two numbers on a supply are matched in two different ways:
- Voltage must match. A 12-volt device goes on a 12-volt supply. Too high and it may be destroyed. Too low and it works badly or not at all.
- Current must be enough. The supply's amp rating must be at least as large as the total its devices draw. Larger is fine.
Conductors and insulators
A material with very low resistance is a conductor. Copper is the usual one. A material with very high resistance is an insulator, such as the plastic jacket around a wire. Cable is simply a conductor to carry the current, wrapped in an insulator to keep it from going anywhere else.
If the two supply wires touch each other with no device between them, the current has a path with almost no resistance. A very large current flows. That is a short circuit, and it is what fuses are for.
Which quantity is it?
Before the numbers, make sure the three ideas are separate in your mind. Pick the quantity each clue describes.
Voltage, current or resistance?
Five clues. Try each one before reading the reason.
Numbers you will meet
Security equipment is low voltage. Most of it runs on 12 or 24 volts, far below the 120 volts at a wall outlet. The figures below are typical. The data sheet for the exact model is the only figure to design with.
| Item | Typical figure | What it tells you |
|---|---|---|
| Wall outlet in the United States | 120 volts | Dangerous. Not low voltage. |
| Access control and alarm power | 12 or 24 volts | The two voltages you will see most. |
| Motion detector | About 20 mA at 12 volts | A very small draw. Dozens fit on one supply. |
| Card reader | 100 to 200 mA at 12 volts | Small, but it adds up over many doors. |
| Magnetic lock | About 500 mA at 12 volts | A large draw, and it is constant. |
| 18 AWG copper wire | About 6.4 ohms per 1,000 feet | Wire is a small resistor that grows with length. |
| 22 AWG copper wire | About 16 ohms per 1,000 feet | Thinner wire, more resistance. |
Get used to moving between amps and milliamps. Move the decimal point three places: 150 mA is 0.15 A, and 2.5 A is 2,500 mA. Add currents only when they are in the same unit.
Three examples
Simple: reading two labels
A keypad's label says "12 VDC, 150 mA". The power supply on the shelf says "Output 12 VDC, 1 A". Check the voltage first: 12 and 12 match. Then the current: the keypad draws 0.15 amps and the supply can deliver 1 amp. The supply is suitable, with room to spare.
Medium: the output that was nearly full
An alarm panel has an auxiliary power output rated 500 mA. It already feeds twelve motion detectors at 25 mA each. Twelve times 25 is 300 mA. A technician adds a keypad that draws 150 mA and a small sounder that draws 100 mA. The total is now 550 mA, which is more than 500.
Nothing fails at once. The sounder is silent most of the time. On the night it sounds, the output is overloaded, its voltage sags and the detectors reset. The cause is a sum that nobody did. The fix is a separate power supply for the new devices.
Advanced: full voltage on the meter, weak siren on the wall
An outdoor siren sits 300 feet from the panel on 22 AWG cable. It sounds feeble. The technician disconnects the siren, measures across the cable's two wires and reads a healthy 13 volts. The cable looks fine.
It is not. The current travels out and back, so it passes through 600 feet of wire, which is close to 10 ohms. With the siren disconnected no current flows, so the wire's resistance costs nothing and the meter shows the full supply voltage. Connect the siren and current flows through that resistance, which uses up part of the push before it reaches the siren. The voltage at the siren falls while it sounds.
The lesson is to measure at the device while the device is working. The cure is thicker wire or a supply nearer the siren. Lesson 3 shows how to work out the loss in volts.
From the field
- Read the label before you connect anything. Voltage first, then current. It takes ten seconds and saves a device.
- Write currents in one unit. Mixing amps and milliamps in the same sum is the most common arithmetic slip in the trade.
- Voltage with nothing connected proves little. A cable with a poor joint can show full voltage on a meter and still starve a device.
- Treat every wire as a small resistor. On a short run you can ignore it. On a long run to a hungry device you cannot.
- Low voltage is not zero risk. A shorted battery or supply can deliver enough current to heat a wire until its jacket melts. Fuse it and keep bare ends apart.
Common mistakes
- Thinking a 5-amp supply will "push" 5 amps into a small device and damage it. The device draws only what it needs.
- Connecting a 12-volt device to a 24-volt output because the plug fitted.
- Adding 150 mA to 2 A and writing 152.
- Sizing a supply for the devices fitted on day one, with nothing left for the next addition.
- Forgetting that current flows out and back, so the wire length that matters is twice the run.
Summary
- Voltage is the push, measured in volts. Current is the flow, measured in amps. Resistance is the narrowness, measured in ohms.
- Current flows only around a complete loop. Break the loop and it stops.
- Voltage is measured between two points and can be present with no current flowing.
- Match the voltage exactly. Make sure the supply's current rating is at least the total drawn.
- Wire has resistance. Longer and thinner means more.
Exercises
Answer each one yourself first, then open the answer.
Exercise 1. Write 350 mA in amps, and 1.2 A in milliamps.
Show answer
Exercise 2. A supply is marked "12 VDC, 2 A". It feeds four readers at 150 mA each and one lock at 500 mA. Is it large enough?
Show answer
Exercise 3. In the tool at the top, set 24 volts and then 12 volts with the same resistance. What happens to the current, and why?
Show answer
Exercise 4 (think, don't memorize). A colleague says: "The meter shows 12 volts at the end of the cable, so the cable is good." The reader on that cable keeps restarting. What would you check, and why might the colleague be wrong?