Codes, Standards and Privacy, lesson 9 of 10
Industry rules
Every building answers to the codes in the earlier lessons. Some customers answer to more: a regulator, an auditor or a contract that adds its own requirements for doors, cameras and records. This lesson introduces the four you will meet most and shows how to find out what a customer is held to.
Rules stacked on rules
Pick a kind of customer and watch what is added on top of the rules every building shares.
The everyday picture
Any kitchen in a house has to meet the building code. A restaurant kitchen has to meet the same code, and then the health department arrives with its own list: where the sinks go, how cold the refrigerators run, what is written down every day. The health inspector does not replace the building inspector. Both come.
Security work has the same second layer. A door in a hospital must satisfy the fire marshal like any other door, and then it must satisfy the people who regulate hospitals. Those people have their own documents, their own inspectors and their own penalties, and they rarely appear on the building permit.
Where extra rules come from
| Source | How it binds the customer | How you find out |
|---|---|---|
| Law and regulation | A federal or state agency regulates the industry and can fine it or close it | Ask which agencies inspect or license the site |
| Conditions of payment or funding | To be paid by a government program, or to receive a grant, the customer must meet set standards | Ask who pays, and what they require |
| Accreditation and audit | An independent body surveys the customer against a standard and issues a report others rely on | Ask for the security findings in the last report |
| Contract | A business partner, card network, insurer or landlord writes requirements into an agreement | Ask what the contracts say about physical security |
The customer is the one bound by these rules, and the customer's compliance staff know them far better than you will. Your part is to ask early, design to what they tell you, and document the system so that it can be shown to an auditor. Some of the obligations then pass down to you by contract, such as background checks for your technicians or limits on what data you may see.
Healthcare
- Life safety, twice. Hospitals and nursing homes that are paid by the federal Medicare and Medicaid programs must meet NFPA 101, the Life Safety Code, in the edition those programs name. That edition can differ from the one the city adopted. Accreditation surveyors walk the building checking doors against it.
- Patient privacy. The federal law known as HIPAA protects health information and includes physical safeguards: controlling who can enter areas where records and systems are kept. It also affects cameras. A picture of a patient, or of a screen showing a chart, can itself be protected information.
- Protecting patients. Maternity units use infant protection systems that lock doors and hold elevators when a tag nears an exit. Behavioral health units need hardware designed so that nothing can be used for self-harm. Units for patients who wander use the controlled egress arrangements from lesson 3.
- Medicines. Federal drug enforcement rules govern how controlled substances are stored and who can reach them.
Working in a hospital has its own rules as well. Before you lift a ceiling tile, the hospital will usually require an infection control assessment and may make you work inside a dust enclosure.
Schools
- Student records. The federal law known as FERPA protects education records. Video that a school keeps and that is directly about a particular student, such as footage of a fight used in a discipline case, can become such a record. That affects who may view it and how parents' requests are handled.
- State school safety laws. Many states have their own requirements: emergency plans, drills, visitor screening, and in a growing number of states silent panic alarms linked to law enforcement.
- Classroom doors. Recent editions of the model codes allow classroom doors to be lockable from inside the room, on conditions: the door still opens from inside with one motion and no key, and staff or responders can unlock it from outside. Add-on barricade devices fail those conditions in many states. A few states permit them. Check before proposing any.
- Children's data. Some states restrict biometric technology, such as face recognition, in schools.
Check yourself
You are designing access control for a clinic. Who is the best first source for the industry rules it must meet?
Finance
- The Bank Protection Act. Federally insured banks must have a written security program and a named security officer, and must install security devices suited to each branch. The bank's regulators examine the program.
- Card data. Any business that handles payment cards agrees by contract to the Payment Card Industry Data Security Standard, known as PCI DSS. Its physical security section asks for controlled, monitored entry to rooms holding systems that store card data, with the entry records kept for a minimum period.
- Customer information. Federal rules require financial firms to safeguard customer information, physically as well as electronically.
- Cash machines. Some states have laws on lighting and cameras at automated teller machines.
Finance customers live by audits. Expect to be asked for device lists, user lists, test records and proof of retention settings every year.
Government
- Federal credentials. Federal employees and contractors carry a standard smart card defined by the federal standard FIPS 201. Access systems in federal buildings are expected to read and verify that card properly, using products from a federal approved list.
- Purchasing restrictions. Federal law bars agencies, and often their contractors and grant recipients, from buying or using video and telecommunications equipment from certain named manufacturers. Country-of-origin rules may apply as well. Check every model before bidding.
- Agency standards. Federal buildings are assigned a security level that sets the measures they need. Areas that handle classified material follow separate, far stricter standards, with their own inspectors.
- Police data. Rooms and systems that handle criminal justice information fall under an FBI security policy. Technicians who work there unescorted usually need a fingerprint-based background check.
- Public records. Video and logs held by a public agency may be open to public records requests, which shapes retention and export.
Others you may meet
| Customer | Who sets extra rules | What it tends to touch |
|---|---|---|
| Electric utilities | The grid reliability regulator's critical infrastructure standards | Controlled, logged entry to control rooms and substations |
| Licensed cannabis businesses | The state licensing agency | Camera coverage, picture quality and a fixed retention period |
| Pharmacies and drug distributors | Federal and state drug regulators | Vaults, cages, alarms and who holds access |
| Airports and seaports | Federal transportation security agencies | Credentials, restricted areas, escort rules |
| Data centers and cloud providers | Customers' auditors, through independent audit reports | Two-step entry, visitor logs, video retention |
Whose rule is this?
Eight requirements, four industries
Pick the industry where you would expect to hear each one.
Three examples
Simple: the camera above the nurses' station
A clinic asks for a camera covering its front desk. The first mounting spot gives a clear view of the staff, and of two computer screens showing patient charts. The installer notices on the test picture.
He moves the camera so the screens face away, adds a privacy mask over the one that is still visible, and notes both in the handover sheet. The clinic's privacy officer signs it. Ten minutes on a ladder avoided a recording system full of protected health information.
Medium: the classroom barricade
After a frightening news story, a parent group buys forty steel bars that drop into brackets on the classroom doors and asks you to fit them. The intention is good. In that state the fire marshal prohibits them: the door would need two actions to open, and responders could not open it from the corridor.
You bring the school, the fire marshal and the parent group to one meeting. The outcome is classroom locks that staff can lock from inside without stepping into the corridor, which still open with the lever from inside and with a key from outside. The parents' money goes toward those locks.
Advanced: the grant-funded police annex
A city builds a police annex with a federal grant. The low bid includes cameras from a manufacturer on the federal prohibited list. The server room will hold criminal justice data. And the city's own purchasing rules require three quotes.
The project manager catches all three at bid review. The cameras are swapped for a compliant model, because the grant terms carry the federal purchasing restriction down to the city. Every technician is fingerprinted before entering the server room unescorted. The retention period is set with the city attorney, who also handles public records requests. None of this was on the building permit.
From the field
- Ask three questions at the first meeting. Who regulates you? Who audits you? What did the last audit say about physical security?
- Get the requirement in the customer's words, in writing, and design to that. Do not design to your memory of another customer's rule.
- Plan for site rules. Background checks, escorts, badging, health screening and infection control can add days before work starts.
- Check every model number against purchasing restrictions before you bid government or grant-funded work.
- Build the audit pack as you go. Device list, door schedule, user roles, retention settings and test records, kept current.
Common mistakes
- Assuming the building permit covers everything the customer must meet.
- Telling a customer a product is "compliant" with an industry rule. Systems and practices comply. Boxes do not.
- Aiming cameras at screens, charts or keypads.
- Fitting door devices in schools without asking the fire marshal.
- Discovering a purchasing restriction after the equipment is on the wall.
Summary
- Industry rules sit on top of the codes that every building shares. They add to them and never replace them.
- They come from regulators, payment and funding conditions, accreditation bodies and contracts.
- Healthcare adds the Life Safety Code and patient privacy. Schools add student records and state safety laws. Finance adds security programs and card data rules. Government adds credentials and purchasing limits.
- The customer's compliance staff are the source. Ask early and get it in writing.
- Design so the system can be shown to an auditor: clear records, set retention, named roles.
Exercises
Answer each one yourself first, then open the answer.
Exercise 1. In the tool at the top, which four layers apply to every building?
Show answer
Exercise 2. A hospital's city adopted one edition of the fire and building codes. Why might its doors also be checked against a different edition of NFPA 101?
Show answer
Exercise 3. A shop takes card payments but keeps no card data on site. A data center stores card data for many shops. Which is more likely to ask you for logged, monitored entry to a server room, and under what kind of rule?
Show answer
Exercise 4 (think, don't memorize). A salesperson at your company wants to print "HIPAA compliant" on the brochure for a video system. What is wrong with the claim, and what could the brochure honestly say?