Codes, Standards and Privacy, lesson 6 of 10
Product standards and listings
An inspector cannot test your controller for fire and shock hazards on site. The mark on its label says somebody already did. This lesson explains what that mark covers, which standards sit behind it, and the things it was never meant to promise.
Read a product label
This is the kind of label found on the back of a door controller. Pick a part of it.
The everyday picture
Think of a child's car seat. Before it can be sold, samples are strapped to a sled and crashed. The label on the seat says it passed. That label is valuable: no parent could run the test at home.
Now notice what the label leaves out. It does not say the seat is comfortable, or the best one in the shop. It does not say the seat fits your car. And it stops meaning anything if you leave the straps loose or cut the shell to make it fit. A listing mark on security equipment works the same way: a real promise, with a narrow scope, that holds only when the product is used as it was tested.
How a product gets listed
- A standard is written. A standards body publishes a document that says how one kind of product must be built and what tests it must survive.
- A laboratory tests samples. The manufacturer sends the product to an independent lab. In the United States these labs are approved by the federal workplace safety agency, OSHA, under the name nationally recognized testing laboratory. UL is the best known. There are others, and their marks carry the same weight for the standards they are approved to test.
- The lab publishes a listing. If the product passes, it is entered in the lab's public directory under a file number, and the manufacturer may put the lab's mark on it. A product in that state is called listed.
- The lab keeps checking. Inspectors visit the factory without warning to confirm that what is being shipped is still what was tested.
The codes then close the loop. The electrical code expects equipment to be listed and to be installed and used as its instructions say. The building code, in recent editions, names the standard that the locking parts of special egress arrangements must be listed to. So the instructions in the box are not advice. They are part of what makes the installation legal.
Listed, recognized, classified
| Word on the label | What was evaluated | What it means for you |
|---|---|---|
| Listed | A complete product, ready to install | Use it as a finished item, following its instructions |
| Recognized component | A part meant to be built into something else at a factory, such as a bare circuit board or an open-frame power supply | It is not approved to be installed by itself in the field. It needs a listed enclosure and a listed assembly. |
| Classified | A product checked for one named property or use only | Read the words beside the mark to see which property. Fire door hardware is often marked this way. |
Some listings go further and grade the product. UL 294, the standard for access control equipment, reports four things separately: resistance to destructive attack, security of the communication line, endurance, and standby power. Each is given a level from I to IV, with IV the most demanding. Two products can both say "UL 294" and have quite different levels, so a specification should name the levels it needs. Door hardware has a similar idea in the industry standards published by BHMA, where Grade 1 is the heaviest duty and Grade 3 the lightest.
Check yourself
A bare power supply board carries a recognized component mark. May you screw it to the wall of a closet and wire locks to it?
Standards you will meet
You do not need to own these documents. You need to recognize the numbers on data sheets and know what each one is about.
| Standard | Covers | Where you see it |
|---|---|---|
| UL 294 | Access control system units: controllers, readers, power supplies and locking parts used with them | Controller and reader labels, and building code sections on special locking |
| UL 1034 | Electric locking mechanisms that resist forced entry | Strikes and magnetic locks |
| UL 10C | Fire tests of door assemblies | Any hardware going on a labeled fire door |
| UL 305 | Panic hardware | Push bars on exit doors |
| UL 864 | Control units for fire alarm systems | The fire alarm panel and the relays that connect to it |
| UL 2043 | Heat and smoke from devices mounted in air-handling spaces | Sensors, speakers and cameras above a plenum ceiling |
| UL 827 | Central station alarm services | The monitoring center, not a product |
| BHMA A156 series | Performance and durability of locks, exit devices, closers, strikes and magnetic locks | Hardware schedules, as a grade |
The last two rows show that standards are not only about boxes. Some apply to a service or to a whole installation. An alarm company can hold a certificate that lets it issue paperwork saying a particular installation meets a standard. Insurers sometimes ask for that. It is a different thing from every component being listed.
What a listing does not promise
- That the product is good. Safety standards ask whether it will burn, shock or fail dangerously. They mostly do not ask whether it is pleasant, fast or reliable over fifteen years.
- That it suits your job. A lock listed for indoor use is still the wrong lock for a gate.
- That your system is listed. Parts are listed for use with named or compatible parts. Mixing a listed controller with an unlisted power supply gives you a system nobody tested.
- That it survives modification. Drilling an enclosure, removing a tamper switch or swapping a transformer takes the product outside what was tested.
- That it is secure against hacking. Most product safety listings say nothing about software security. Separate cybersecurity standards exist, and the Cybersecurity course covers the subject.
- That other marks mean the same thing. The FCC mark concerns radio interference. The CE mark is the manufacturer's own declaration for the European market. Neither is a listing by a United States testing lab.
Does the mark promise this?
Seven claims about a listed product
Decide whether the listing supports each claim.
Three examples
Simple: the plug-in adapter
A reader's listed power supply fails on a Friday. The technician finds a plug-in adapter of the right voltage in the van, with no lab mark on it, and fits it "for now". The reader works. The installation is now outside its listing, and nobody knows what that adapter does when it is shorted.
The right temporary fix is a listed Class 2 supply of the correct rating, which costs little more. "For now" parts have a way of still being there at the next inspection.
Medium: two bids that both say UL 294
A hospital specification asks for access control equipment "listed to UL 294". Two bidders comply. After award, the engineer finds that the cheaper system's listing shows the lowest level for standby power, and the hospital expected doors to keep working through an outage.
The fault is in the specification. It should have named the level required in each of the four categories. The engineer now does that on every project, and asks for the listing page from the lab's directory with each submittal.
Advanced: the strike on the fire door
A stair door needs an electric strike. The door, frame and existing latch are a labeled fire assembly. The installer has a strike in stock that is listed to UL 1034 for burglary resistance, and assumes "listed" covers it.
It does not. Burglary resistance and fire performance are different tests. Hardware for that opening must be labeled for use on fire doors, tested to the fire door standard, and the frame preparation must stay within what NFPA 80 allows. He orders a strike that carries the fire label, checks its instructions for the frame types it was tested in, and keeps the cut sheet with the door inspection records.
From the field
- Look the product up. Each lab has a free online directory. Search the file number or model and read what the listing actually covers.
- Keep the instruction sheet. File it with the job. It is the document an inspector will measure the installation against.
- Read the compatibility list. Controllers, readers and power supplies are often listed only with named partners.
- Do not drill a listed enclosure where the instructions do not show a knockout without checking. Use the entries provided.
- Be wary of a mark with no file number, a blurred logo or a price far below the market. Counterfeit marks exist.
Common mistakes
- Saying "UL approved". Labs list, recognize or classify. Approval comes from the authority having jurisdiction.
- Treating a recognized component as a finished, installable product.
- Assuming one listing covers every use: burglary, fire, plenum and outdoors are separate.
- Reading FCC or CE as a safety listing.
- Throwing away the instructions.
Summary
- A listing means an independent lab tested samples against a named standard and keeps checking the factory.
- Listed is a finished product, recognized is a factory component, classified covers one named property.
- The listing holds only when the product is installed as its instructions say, with compatible parts, unmodified.
- UL 294 reports levels in four categories. Specify the levels, not only the number.
- A listing is about safety and tested performance. It is not a judgment of quality, fitness for your job or cybersecurity.
Exercises
Answer each one yourself first, then open the answer.
Exercise 1. On the label at the top, which part tells you whether the outputs may feed light cable without conduit?
Show answer
Exercise 2. What are the four categories that a UL 294 listing reports a level for?
Show answer
Exercise 3. A camera's box shows only FCC and CE marks. The job needs it mounted above a plenum ceiling. What is missing?
Show answer
Exercise 4 (think, don't memorize). A customer says, "All three quotes use listed equipment, so they are equal. I will take the cheapest." What questions would you suggest they ask?