A secured door that a wheelchair user cannot open is a locked door for that person. This lesson explains what the Americans with Disabilities Act and its design standards ask of doors, readers and intercoms, and how to build entrances that work for everyone the first time.

About 14 minutes. Read lesson 2 of this course first.

Can everyone reach it?

Choose a device and slide it up and down the wall. The shaded band is the reach range in the 2010 ADA Standards for a clear approach with nothing in the way.

48 inches 15 inches wall 24 in48 in72 in clear floor space in front of the device

The everyday picture

Think of the sloped cut in a sidewalk curb at a street corner. It was put there for people who use wheelchairs. Watch who uses it: parents with strollers, travelers with rolling bags, delivery workers with hand trucks, a child on a scooter.

Accessible design works like that. A reader at a height a seated person can reach is also easier for a short person, for someone with a shoulder injury and for someone carrying a box. A door that gives a slow walker time to get through gives everyone time. The aim of this lesson is not a list of numbers to pass. It is an entrance that a person can use without asking for help.

A civil rights law, not a building code

The Americans with Disabilities Act, or ADA, is a federal civil rights law. It says people with disabilities must be able to use public buildings, businesses and workplaces. The technical detail lives in a separate document, the 2010 ADA Standards for Accessible Design, usually called the ADA Standards.

That makes it different from everything else in this course, in three ways.

Building code accessibilityThe ADA
What it isA chapter of the adopted building code, which usually points to a technical standard named ICC A117.1Federal civil rights law, with the ADA Standards as its measure
Who enforces itThe local building official, at plan review and inspectionThe Department of Justice, and private people through complaints and lawsuits
When it bitesWhen work needs a permitAt any time. Existing buildings open to the public are expected to remove barriers where that can readily be done.

Two consequences follow. A building inspector's sign-off does not mean the ADA is satisfied, because the inspector does not enforce it. And the requirements overlap but are not identical. Some states, California among them, have accessibility rules stricter than either. Where they differ, build to the strictest.

What it asks of a door

These figures are from the 2010 ADA Standards. Your state's code may differ, so treat them as the starting point and check the adopted text.

FeatureWhat the Standards askWhy a security installer cares
Clear widthAt least 32 inches with the door open 90 degreesA magnetic lock, bracket or surface strike must not narrow the opening
HardwareUsable with one hand, with no tight grasping, pinching or twisting of the wrist, mounted between 34 and 48 inchesLevers and bars pass. Round knobs and small thumb-turns do not.
Opening forceNo more than 5 pounds on interior hinged doors. Fire doors are set by the fire authority.A stronger closer fitted so the door latches against a seal can push it over the limit
Closing speedWith a closer, at least 5 seconds to move from 90 degrees to 12 degrees from the latchSpeeding the closer up to beat tailgating breaks this
ThresholdNo more than half an inch highSurface raceway or a sensor strip across the floor counts
Space to maneuverClear floor beside and in front of the door. On the pull side, a front approach needs 18 inches beside the latch.A pedestal, bollard or cabinet placed there blocks the door for a wheelchair user

Check yourself

The city inspector passed a new entrance last month. A visitor who uses a wheelchair now complains that she cannot reach the card reader. Does the sign-off settle the matter?

Readers, buttons and keypads

The Standards call anything a person must touch or operate an operable part. Card readers, keypads, call buttons, exit buttons and door actuators are all operable parts. Four rules cover most of them.

  • Height. With a clear approach, the part must be between 15 and 48 inches above the floor. If the person has to reach over something, such as a counter or a planter, the upper limit drops. Try it in the tool at the top.
  • Clear floor space. A level space of 30 by 48 inches in front of the device, so a wheelchair can pull up to it. It should be outside the swing of the door.
  • Operation. One hand, no tight grasping, pinching or twisting, and no more than 5 pounds of force. A card held near a reader passes easily. A small stiff keypad or a fingerprint reader that needs a precise press may not.
  • Nothing sticking out. An object mounted between 27 and 80 inches above the floor may project no more than 4 inches into a walkway, because a person using a cane will not find it. A reader is thin enough. A deep intercom box or a camera on a low bracket may not be.

Position matters as much as height. Mount the reader on the latch side, close to the door, so a person can present a card and reach the handle without turning around. For a turnstile lane, provide an accessible gate next to it with its own reader.

Then there is time. The lock relocks a few seconds after a card is read. A person with a walker may need three times as long to reach the handle. Most access systems let you mark a cardholder for a longer unlock and a longer door-held-open time. Use it, and tell the people who issue cards that it exists.

Intercoms and powered doors

Where a two-way communication system is the way to gain admittance, the Standards ask for both audible and visual signals. A visitor who is deaf must be able to see that the call was placed and that the door has been released. Look for stations with indicator lights or a screen, and avoid designs that depend on hearing a buzz.

A powered door operator and a card reader have to be made to work together. On a secured door, the wall actuator should do nothing until a valid card is read. Then the lock must release before the operator starts to push, or the operator will strain against a locked door. The operator must hold the door open long enough to pass, and from the inside the actuator must always work. Sequencing modules exist for exactly this.

Staff are covered too. An employee with a disability is entitled to reasonable changes that let them do the job, which can mean an alternative to a fingerprint reader or an operator on a heavy door. That is an employment law question. Refer it to the employer's human resources or legal adviser and build what they decide.

Audit six entrances

Usable by everyone, or a barrier?

Judge each entrance, then read why.

Three examples

Simple: the reader at eye level

An installer mounts every reader with its center 60 inches from the floor, because that is where his own hand falls. On the first day a staff member who uses a wheelchair cannot badge in. The readers come down to 42 inches, inside the range and comfortable for standing users too. The holes in the wall are patched at the installer's cost.

Medium: the closer and the weatherstrip

A side door will not latch against its new weatherstrip, so the door-forced alarm keeps sounding. A technician turns up the closer until it slams shut. The alarm stops. The door now takes a hard pull to open and closes in two seconds.

Both changes are barriers. The right fix is at the source: adjust or replace the seal so the latch is not under pressure, then set the closer back so the door takes at least 5 seconds to swing to the latch. If the door still needs more force than a person can manage, a powered operator is the answer.

Advanced: the lobby with optical turnstiles

An office tower adds a row of optical turnstiles and a visitor intercom at the street door. The first design has four narrow lanes, readers on top of the cabinets, and an audio-only intercom.

The reviewed design adds one wide lane with a swinging gate, a reader on its side panel within reach of a seated person, and a longer passage time on that lane. The intercom is changed to a video station with indicator lights, mounted with its call button inside the reach range and clear floor in front. The visitor desk is told that the wide lane is for anyone who asks, without questions. The owner's accessibility consultant signs off on the drawings before the order is placed.

From the field

  • Carry a tape and a door pressure gauge. Measure reader height to the part that is touched, and measure opening force after you adjust anything.
  • Sit down and try it. Borrow a chair, roll up to the reader, present a card and reach for the handle before the lock relocks.
  • Set one mounting height for the whole site and write it on the drawings. 42 inches to the center is a common choice that suits most people.
  • Check the swing. If the open door covers the reader or the clear floor space, move the reader.
  • Ask who the owner's accessibility contact is. Larger organizations have one, and they would rather be asked before than after.

Common mistakes

  • Treating an inspector's approval as proof that the ADA is met.
  • Mounting readers and buttons high to keep them from children or vandals.
  • Speeding up or stiffening a closer to cure a latching or tailgating problem.
  • Fitting an intercom that gives no visual sign of a call or a release.
  • Wiring a door operator without sequencing it with the lock.

Summary

  • The ADA is civil rights law, enforced separately from the building code, and it applies to existing buildings too.
  • The 2010 ADA Standards put operable parts between 15 and 48 inches for a clear approach, with clear floor space in front.
  • Parts must work with one hand, no tight grasp or twist, and little force.
  • Doors need width, low opening force and slow closing. Security changes must not take those away.
  • Intercoms need visual signals, turnstiles need an accessible lane, and unlock times must suit slow users.

Exercises

Answer each one yourself first, then open the answer.

Exercise 1. In the tool at the top, find the highest and lowest heights that pass. What are they?

Show answer
48 inches and 15 inches, for a clear approach with nothing to reach over. If there is an obstruction in front of the device, the limits tighten and you must read the reach tables in the adopted standard.

Exercise 2. A door closer takes 3 seconds to swing the door from 90 degrees to 12 degrees from the latch. Does that meet the figure in this lesson?

Show answer
No. The 2010 ADA Standards ask for at least 5 seconds. The closer's sweep speed needs to be slowed.

Exercise 3. Why is a round door knob a problem, when a lever is not?

Show answer
A knob has to be gripped tightly and twisted. Many people with arthritis, limited hand strength or a prosthesis cannot do that. A lever can be pushed down with a closed fist or an elbow.

Exercise 4 (think, don't memorize). A daycare asks for the exit push button to be mounted at 60 inches so that toddlers cannot let themselves out. What do you say?

Show answer
The goal is sound, and the method fails two tests. At 60 inches the button is out of reach for a seated adult, and a button needed to get out is part of the exit route, where the life safety rules from the Access Control course apply as well. There are approved ways to protect children at exits, and which ones are allowed depends on the adopted code and the licensing agency. Put the question to the AHJ and the daycare's licensing body before fixing a height, and get the answer in writing.