Alarm Monitoring, lesson 5 of 10
Verification
Lesson 4 showed the operators and the written procedures they follow. Much of their work comes down to one question: is this alarm real? Most burglar alarm signals are not burglaries. They are staff who forgot a code, doors that did not latch and sensors in the wrong place. This lesson shows the methods for finding out in a minute or two, and how much each one tells you.
Weigh the evidence
A shop is armed at 2 a.m. and the back door trips. Change what the operator learns, and see what happens next.
The everyday picture
Your neighbor's car alarm goes off at night. You do not call the police at the first chirp. You look out of the window. If you see the neighbor fumbling with the keys, you go back to bed. If you see a stranger with a crowbar, you call at once, and you tell the police exactly what you see. If you see nothing, you listen for a while and perhaps phone the neighbor.
Looking, listening and phoning before you act is verification. Notice that what you saw also changed what you said. "A car alarm is sounding" and "a man is breaking into a blue sedan" get very different responses. The same is true for a monitoring center.
Why verify at all
Police departments across the country report that the great majority of the alarm calls they attend, commonly put at well over nine in ten, turn out to be false. Every one takes officers away from other work. Cities have answered with fines, lower priority for alarm calls and, in some places, a refusal to attend unverified alarms at all. Lesson 9 covers those rules.
So verification has two purposes. It stops police being requested for the cleaner who forgot her code. And when the alarm is real, it gives the dispatcher better information, which can raise the priority of the call.
A false alarm, in most ordinances, is any alarm that brings a responder when there was no emergency. The cause does not matter. A false dispatch is the narrower thing that verification prevents: a request for police that need not have been made.
Verification is for burglary signals. Fire signals are generally dispatched at once. Holdup, panic and duress signals are generally dispatched without a call to the building, because a ringing phone could endanger the person who pressed the button. Always follow the center's procedure and the local rules.
Four ways to verify
| Method | How it works | What it tells you | Limits |
|---|---|---|---|
| Two phone calls | The operator phones the building, then a second number for a responsible person, before requesting police | Whether an authorized person is there, or knows why the alarm tripped | Tells you nothing if nobody answers |
| A second sensor | The operator, or the panel, waits to see whether a different zone trips soon after the first | Something is moving through the building. One faulty sensor cannot do that. | A real intruder who stays in one room trips one zone |
| Sound | Microphones at the site let the operator listen in after an alarm | Voices, breaking glass, footsteps | Silence proves little. Privacy law applies to recording sound. |
| Video | A camera sends a short clip or live view linked to the alarm | A person, and often what they are doing | A camera sees one area. An empty picture does not prove an empty building. |
The trade name for the first method is enhanced call verification: at least two calls, to two different numbers, before a burglary dispatch. It is written into an industry standard and into the law of a number of states and cities. It is cheap, needs no extra equipment and removes a large share of false dispatches.
An alarm backed by sound, video or an eyewitness is often called a verified alarm. Some police departments give such calls a higher priority, and a few attend nothing else. Where that policy applies, it is called verified response.
Check yourself
A holdup button is pressed at a bank counter. What does the operator normally do first?
Passcodes and duress
When someone answers the phone at an alarmed building, the operator asks for the passcode. Three things can happen.
- The right passcode. The person is authorized. The operator closes the alarm and records the name given.
- A wrong passcode, or none. The operator cannot tell staff from a burglar by voice, so the procedure carries on as if nobody had answered. This is not rudeness. It is the only safe rule.
- The duress passcode. An account can hold a second word that means "I am being forced to say everything is fine". The operator answers normally, ends the call, and requests police as for a holdup.
A panel can have a duress code as well: a keypad code that disarms the system normally while sending a silent signal. Both features cause false dispatches when people use them by mistake, so teach them carefully or leave them out.
Help from the panel
Some verification happens before any signal is sent. An industry standard for control panels, aimed at reducing false alarms, sets out features that most modern panels include. The default times below are typical. Check the panel's guide and any local rule.
| Feature | What it does | Typical setting |
|---|---|---|
| Entry and exit delay | Time to reach the keypad on the way in, and to leave on the way out | 30 seconds in, 60 seconds out |
| Abort window | Holds the alarm message briefly so a user can disarm before it is sent | 30 seconds |
| Cancel | If a user disarms shortly after the alarm was sent, the panel sends a cancel message | Within 5 minutes |
| Cross zoning | Two chosen zones must both trip within a set time before an alarm is sent | Set per pair of zones |
| Swinger shutdown | A zone that trips repeatedly in one armed period stops reporting after a set number of trips | After 1 or 2 trips |
Use cross zoning with care. It quiets a troublesome area, but if one of the two sensors fails, the pair may never alarm. Pair sensors that a real intruder would have to pass, and test both.
Request police, or not yet?
Six moments from an operator's night. For each, decide whether the operator should request police now. These follow common practice. Your center's procedure is the authority.
What should the operator do?
Three examples
Simple: the second call
A front door alarm arrives from a bakery at 4:40 a.m. The bakery's phone rings out. Under the old one-call procedure, police would be requested now. The operator makes the second call, to the owner's cell phone. The owner is standing in the kitchen with flour on her hands. The new baker had come in early. No dispatch, no fine, and a note on the account that the baker needs a code.
Medium: a picture changes the call
A motion alarm arrives from a builder's yard with a camera tied to the sensor. The ten-second clip shows two people lifting a generator toward the fence. The operator skips the phone calls, as the plan allows for video evidence of a crime, and tells the dispatcher: "video shows two people removing equipment, rear fence, now". The call is treated as a crime in progress, not as an alarm.
Advanced: verification that hid a break-in
A warehouse has cross zoning on its loading bay: the bay door contact and a motion sensor must both trip. The motion sensor has been blocked for months by a stack of pallets. One night the door is forced. One zone trips, the second never does, and no alarm is sent.
The feature worked as programmed. The design was wrong: the pair depended on a sensor nobody had walk-tested since the racking was moved. The repair is a walk test after every change to the room, and a rule that a single trip from a perimeter door still sends a signal, even if a lower-priority one.
From the field
- Put two different numbers at the top of every burglary account: the building, then a cell phone that is answered at night.
- Tell contacts to save the center's number in their phones. People do not answer unknown callers at 3 a.m.
- Give every key holder a code and a passcode on the same day as the key.
- Aim verification cameras at the way in, with light enough to see a person at night, and test the clip from the center's end.
- Walk-test both halves of every cross-zoned pair after any change to shelving, stock or walls.
Common mistakes
- Listing the building's own number twice, so the "second call" rings the same empty room.
- Treating a restore, or a silent phone, as proof that all is well.
- Asking for calls before dispatch on holdup or fire signals.
- Lengthening delays and adding cross zones until a real intruder has time to finish.
- Fitting microphones or cameras without checking the privacy rules and posting the notices they require.
Summary
- Most burglary signals are false, so operators check before requesting police.
- Two calls to two numbers is the basic method. A second sensor, sound and video add evidence.
- A right passcode closes an alarm. A wrong one does not. A duress word brings police quietly.
- Panel features such as the abort window, cancel and cross zoning stop many false alarms at the source.
- Fire, holdup and duress signals are not verified by phone first.
Exercises
Answer each one yourself first, then open the answer.
Exercise 1. What makes a call procedure "enhanced" call verification?
Show answer
Exercise 2. In the tool at the top, choose "Answered, wrong passcode". Why does the operator still request police when a person has plainly answered the phone?
Show answer
Exercise 3. A user disarms 50 seconds after the siren starts, on a panel with a 30-second abort window and a 5-minute cancel window. What does the center receive?
Show answer
Exercise 4 (think, don't memorize). A shop owner tired of false alarm fines asks you to cross-zone every sensor in the building and set the entry delay to four minutes. What do you say?