PanelSimulator Academy

Alarm Monitoring, lesson 3 of 10

Signal formats

Lesson 2 showed the roads an alarm message travels. This lesson looks at the message itself. An alarm panel does not send a sentence. It sends a short string of numbers, and the monitoring center's software turns those numbers back into words. Here you will see what the numbers are, how to read them, and why a wrong number in programming sends help to the wrong place.

About 14 minutes. Read lessons 1 and 2 first.

Build a message

Choose what happened at the building. The top row is what the panel sends. The screen is what the operator reads.

what the panel sends, in the Contact ID format 4417 18 1 131 01 003 Accountwho is calling Typeformat Qualifiernew Event codeburglary Areaarea 1 Zone or userzone 3 the center's records add the words Acct 4417: Corner Hardware, 212 Mill St

The everyday picture

A restaurant kitchen works from tickets. The server does not write "the couple by the window would like the grilled fish, please". The ticket says table 12, item 31, no butter. It is short, it is hard to misread, and it only makes sense because the kitchen has the same menu the server has.

An alarm message is a kitchen ticket. It says which customer, what happened and where, in numbers. The monitoring center holds the "menu" for each customer: the record that says account 4417 is Corner Hardware and zone 3 is the back door.

If the menu and the ticket disagree, the kitchen cooks the wrong dish, perfectly. Much of this lesson is about keeping the two in step.

What a message contains

The most widely used format in the United States is Contact ID. Each message has the same fields in the same order.

FieldDigitsMeaning
Account4Which customer's panel is calling. Set by the monitoring center, programmed by the installer.
Message type2Tells the receiver this is a Contact ID message. Normally 18.
Qualifier11 means a new event, or an opening. 3 means a restore, or a closing.
Event code3What happened: burglary, fire, power loss and so on.
Area2Which part of a divided system. A divided part is called a partition or area. 00 means the whole system.
Zone or user3Which sensor circuit tripped, or which person's code was used

A final check digit follows, worked out from all the others. If any digit is garbled on the way, the sum no longer fits and the receiver rejects the message.

Two words in that table need explaining. A zone is one sensor, or one group of sensors, that the panel treats as a single point. A restore is the message that says a condition has ended: the door closed again, the power came back. A restore does not mean an alarm was canceled. It only means the sensor is back to normal. A burglar who closes the door behind him produces a restore.

Opening and closing are the trade's words for disarming and arming, from the days when a shop opened and closed. These messages carry a user number in the last field, so the center can record who opened up.

Common event codes

Contact ID groups its codes by the first digit. Codes in the 100s are alarms, the 300s are troubles, the 400s are openings and closings, the 500s are bypasses and disables, and the 600s are tests. Panels differ in which codes they use, so read the panel's programming guide.

Contact IDSIAEventUsual handling
100MAMedical alarmOperator, high priority
110FAFire alarmOperator, highest priority
120PAPanic alarmOperator, high priority
130 to 134BABurglary, with the kind of zoneOperator
301ATAC power lostOften held a while, then the customer is told
302YTLow system batteryCustomer told in business hours
401OP, CLOpened or closed by a userLogged. Checked against a schedule if the customer pays for that.
602RPPeriodic testLogged by the software. No person sees it.

Check yourself

Two minutes after a burglary alarm on zone 3, the center receives the same event code and zone with qualifier 3. What does that tell the operator?

The formats you will meet

  • Pulse formats. The oldest dialers sent a four-digit account and a two-digit code as bursts of tone. The code had no built-in meaning: 31 meant whatever a table agreed with the center said it meant. You will still find these on old panels. They are slow and carry little.
  • Contact ID. Described above. Compact, numeric, and understood by nearly every receiver.
  • SIA format. Uses two-letter codes in place of three-digit numbers, such as BA for a burglary alarm and OP for an opening. It can carry more detail, and some versions carry text.
  • Internet reporting. Over the internet or cellular data, the same Contact ID or SIA content travels inside a data message. The common standard for this is SIA DC-09. It adds a time stamp, a confirmation from the receiver and optional encryption.

The center tells you which formats its receivers accept, and gives you the receiver's phone numbers or network address and the account number. Program exactly what it gives you.

Handshake and confirmation

A dialer does not simply talk into the line. The receiver answers and sends a short tone called the handshake, which says "ready, and here is the format I expect". The panel sends its message. If the check digit fits, the receiver sends a second tone, the kissoff, which says "received". Only then does the panel hang up.

With no kissoff, the panel sends again, and after a set number of failed attempts it shows "failure to communicate" at the keypad. Internet formats do the same thing with a data reply in place of a tone. The principle is the one to remember: a panel never assumes that a message arrived. It waits to be told.

Read five messages

Each message below arrived for account 4417. Area 1 is the shop. Zone 3 is the back door, zone 5 is the hall smoke detector, and user 2 is the manager.

What does it say?

Three examples

Simple: the wrong words

A technician adds a motion sensor in a stockroom as zone 7 and forgets to tell the center. Months later it trips. The operator's screen says "burglary, zone 7" with no description. The operator tells the dispatcher "zone 7, location unknown", and officers check the front and leave.

The panel sent a correct message. The menu was out of date. Every change to zones must reach the center the same day.

Medium: the wrong account

Two neighboring shops are fitted in one week. The second panel is programmed with the first shop's account number, copied from the wrong sheet. Its test signals arrive without complaint, because the account exists. When the second shop has a break-in, the operator phones the first shop's owner and sends police to the first shop's address.

The cure is in the handover test. Trip a zone, phone the center, and ask the operator to read back the account name and address, not only the zone.

Advanced: an opening nobody expected

A pharmacy pays for open and close supervision. The center holds a schedule: opened no earlier than 7:30 a.m., closed by 9:30 p.m. At 3:12 a.m. the center receives an opening by user 4.

Nothing is in alarm. The system was disarmed with a valid code. But the software flags an opening outside the schedule and an operator phones the owner, who confirms that user 4 is a former employee. The code was never deleted. Without the opening report and the schedule, the center would have seen nothing at all, because a disarmed system sends no burglary alarms.

From the field

  • Send the zone list to the center in writing, with descriptions a stranger could act on. "Rear roll-up door, alley side" beats "zone 6".
  • Have the operator read back the account name and address at the end of every test.
  • Turn on restores and cancels. They cost nothing and give the operator the full story.
  • Trip one of each kind of event during commissioning: a burglary zone, the fire zone, a panic button, an AC loss and a low battery if you can. Check each arrives with the right code.
  • Keep user numbers matched to names at the center when codes are added or deleted.

Common mistakes

  • Copying an account number from another job.
  • Adding or renumbering zones without updating the center's record.
  • Reading a restore as a cancel.
  • Leaving the panel on a format the receiver line does not accept, so every signal fails after the handshake.
  • Programming a 24-hour panic zone with a burglary code, so the operator phones the building before sending help.

Summary

  • A message is a short string of numbers: account, qualifier, event code, area, and zone or user.
  • The center's record turns the numbers into a name, an address and a location in the building.
  • Qualifier 1 is a new event or an opening. Qualifier 3 is a restore or a closing.
  • Contact ID and SIA are the two main formats. Over the internet they travel inside a data message with a confirmation.
  • The panel repeats a message until the receiver confirms it.

Exercises

Answer each one yourself first, then open the answer.

Exercise 1. In the Contact ID message 4417 18 1 110 01 005, which digits are the event code, and what is the event?

Show answer
110, a fire alarm. It is a new event (qualifier 1) in area 1 on zone 5.

Exercise 2. What does the last field hold in an opening or closing message?

Show answer
The number of the user whose code armed or disarmed the system, in place of a zone number.

Exercise 3. A panel dials, the receiver answers, and the panel sends its message four times before giving up. What did the panel not receive?

Show answer
The kissoff, the receiver's confirmation. Likely causes are a format the receiver does not expect, an account number of the wrong length, or a line that garbles the tones, such as an internet phone service.

Exercise 4 (think, don't memorize). A customer asks why you want a written description for every zone. "The panel already knows which sensor it is."

Show answer
The panel knows a number. The person who has to act is an operator hundreds of miles away, speaking to a dispatcher, who will tell an officer where to look. "Zone 6" sends the officer to the front door. "Rear roll-up door, alley side" sends the officer to the alley. The description is the only part of the message a human can use, and it lives at the center, not in the panel.