Alarm Monitoring, lesson 1 of 10
From sensor to dispatcher
A siren on a wall only helps if somebody hears it and acts. Monitoring is the arrangement that makes sure somebody does. This lesson follows one alarm signal from the sensor that trips to the officer who arrives, and shows who does what along the way.
Follow one alarm
Pick a situation, then play or step through it.
The everyday picture
Think of a smoke detector in an empty house. It can scream all afternoon. If nobody is home and the neighbors are at work, the house still burns.
Now picture a hotel. A guest who needs help picks up the room phone. The front desk answers at any hour, asks a short question or two, and calls the right service. The guest does not need to know the number for the fire department or the name of the night manager. The desk does.
Alarm monitoring gives a building a front desk. The alarm system makes the call, a trained person answers, and that person knows who to send. The building can be empty, and the owner can be asleep or on a plane.
The links in the chain
Six links carry an alarm from the sensor to the street. The Intrusion Detection course covers the first two in detail. This course is about everything after them.
- Sensor and panel A sensor notices a door opening, motion, smoke or a pressed button. The control panel decides whether that counts as an alarm right now. An armed system and a disarmed one treat the same open door differently.
- Communicator and path The communicator is the part of the panel that sends messages out of the building. The route it uses is the path: a phone line, the internet or a cellular radio.
- Receiver and software At the monitoring center, a receiver answers the message and passes it to the monitoring software. The software looks up the sender's account number and opens that customer's record.
- Operator A trained person reads the alarm, follows the written steps for that account, and tries to find out whether it is real. This is called verification.
- Dispatcher The operator asks the local 911 center to send police, fire or medical help. Asking for that help is called dispatch. The 911 center, not the monitoring center, decides which unit goes and when.
- Keyholder A person named by the owner who can come to the building with a key and the alarm code. Officers cannot reset a panel or lock a broken door. Somebody has to.
You will hear two names for the place where signals arrive. Central station is the older trade term and is still used in standards. Monitoring center means the same thing in everyday speech. This course uses both.
One point surprises newcomers. The monitoring center is usually nowhere near the building. One center may watch accounts in forty states. That is why it cannot simply dial 911, which reaches the 911 center nearest the caller. The operator keeps the direct phone number of the 911 center that serves each customer's address, and calls that.
Check yourself
Who decides which police car goes to an alarm, and how quickly?
Where the time goes
People imagine that an alarm reaches the police in a second. The message itself does travel in seconds. Most of the time is spent on purpose, in pauses that exist to stop false alarms, and in the human steps at each end.
| Stage | What is happening | Typical time |
|---|---|---|
| Entry delay | The panel waits for someone to enter a code after an entry door opens | 30 to 60 seconds |
| Abort window | The siren is sounding, but the panel holds the message briefly in case a user disarms | Often 30 seconds on home systems |
| Transmission | The communicator sends the message and waits for the receiver to confirm it | A few seconds, longer on an old phone dialer |
| Operator pickup | The alarm waits its turn, then an operator opens it | Seconds when quiet, longer in a storm |
| Verification | The operator phones the building, then the contact list | One to three minutes |
| Dispatch and travel | The 911 center ranks the call against others and sends a unit | Minutes to much longer. Set by the city, not by you. |
The first two rows only apply to burglar alarms on doors that people use. A motion sensor in a room that should be empty, a fire alarm and a panic button skip them and send at once. Lesson 5, Verification, explains these pauses and when they are skipped.
The practical lesson for a designer is plain. Monitoring does not stop a burglar. It starts a clock. Good locks and doors buy the minutes that the clock needs.
Three ways to be monitored
| Local alarm only | Self-monitored | Professionally monitored | |
|---|---|---|---|
| Who is told | Anyone within earshot | The owner's phone | A staffed center, all day and night |
| Who calls for help | A neighbor, perhaps | The owner, if they see the alert | A trained operator following written steps |
| Weak point | Nobody listening | A phone that is off, silenced or in a tunnel | Wrong contact details and a single path |
| Monthly cost | None | Low or none | A monthly fee |
Self-monitoring suits a low-risk site with an owner who is always reachable. It does not suit fire alarms in commercial buildings, where codes generally require a listed supervising station. It also has the 911 problem in reverse: an owner on vacation who dials 911 reaches a center a thousand miles from the building.
Add up the minutes
Put in the settings of a system and an estimate for your city. The figures are examples. Ask the local police department what its response time to alarm calls really is.
From the door opening to an officer at the door
With the starting figures, the center knows after 65 seconds: 30 of entry delay, 30 of abort window and about 5 to send. Pickup and two phone calls add 120 seconds, so police are requested at 3 minutes 5 seconds. Twelve minutes later an officer arrives, a little over 15 minutes after the door opened.
Three examples
Simple: a shop at night
At 2:10 a.m. the back door of a hardware store is pried open. The panel is armed. No code is entered, the siren sounds, and the alarm reaches the center. The operator phones the store, gets no answer, phones the owner, who says nobody should be there, and calls the city's 911 center. An officer arrives and finds the door open. The owner arrives ten minutes later with the key and the code. Every link did its job.
Medium: the new cleaner
A cleaner starts at an office and was given a key but not a code. She opens the door at 6 a.m. and the siren sounds. The operator phones the office. She answers, but she does not know the passcode, the spoken word that proves a person is allowed to be there. The operator cannot tell a cleaner from a burglar by voice, so the procedure continues, and police are sent to a false alarm.
The fault was not in any equipment. The fix is a code and a passcode for the cleaner, and a rule that nobody gets a key without both.
Advanced: one building, two kinds of signal
A small warehouse has one panel for burglary and a separate fire alarm panel. On the same night a rooftop unit fails and trips a duct smoke detector, and wind rattles a loading door enough to trip its contact.
The operator handles the two signals in opposite orders. For the fire signal, the fire department is requested first and the contacts are phoned afterward, because a fire grows by the minute. For the burglary signal, the calls come first, because the great majority of burglar alarm signals turn out to be false. The owner is surprised to meet fire engines for a broken fan. That is the system working as fire codes intend.
From the field
- Tell the center before you test. Ask for the account to be placed "on test" for a set time. Signals are still logged, but nobody is dispatched.
- Read the signals back after testing. Phone the center and ask what they received. A siren proves the panel works. Only the center's log proves the chain works.
- Check the address on the account, including the suite number and the cross street. The dispatcher sends officers to what the operator reads out.
- Explain the pauses to the customer. People who know about the entry delay and abort window stop panicking at the keypad, and make fewer mistakes.
- Write the center's phone number and the account number inside the panel door. The next technician will thank you.
Common mistakes
- Believing the monitoring center sends the police. It asks. The city decides.
- Giving out keys without codes and passcodes.
- Leaving a contact list unchanged for years while staff come and go.
- Testing the siren and never checking what reached the center.
- Selling monitoring as protection. It is notification. Locks, doors and safes do the protecting.
Summary
- An alarm travels from sensor to panel, through a communicator and path, to a receiver, an operator, a dispatcher and a responder.
- The monitoring center verifies and requests help. The local 911 center sends it.
- Most of the delay is deliberate pauses and human steps, not the message itself.
- Fire and panic signals are dispatched first. Burglary signals are usually checked first.
- The chain is only as good as its records: address, contacts, codes and passcodes.
Exercises
Answer each one yourself first, then open the answer.
Exercise 1. Name the part of the panel that sends messages out of the building, and the part of the monitoring center that answers them.
Show answer
Exercise 2. A system has a 45-second entry delay and a 30-second abort window. Roughly how long after a burglar opens the front door does the center first learn of it?
Show answer
Exercise 3. Why does a monitoring center in another state not simply dial 911 for a customer?
Show answer
Exercise 4 (think, don't memorize). A jeweler says, "I pay for monitoring, so the police will be here before a thief can take anything." What do you tell him?