PanelSimulator Academy

Access Control, lesson 5 of 14

Electric locks

Lesson 1 followed a card from the hand to an open door. The controller's decision in the middle of that journey ends as a small movement of metal. This lesson shows the three ways that movement is made, what each one does in a power cut, and how to pick the right one for a door.

About 15 minutes. Read lesson 1 first.

Look inside the opening, from above

Pick a kind of lock, then play or step through one entry.

inside the room outside seen from above magnet, holding Door outside handle hinge Frame

The everyday picture

Think of three ways to keep a garden gate shut.

You could fit a catch on the gatepost that normally grips the gate's latch and lets go when you press a button. You could hold the gate shut with a strong magnet that you switch off. Or you could put a lock in the gate itself, so the handle refuses to turn until it is released.

Those are the three families of electric lock. The first works on the frame, the second holds the door directly, and the third lives inside the door.

Three families of lock

  • Electric strike Replaces the metal plate in the frame. Its hinged lip, the keeper, holds the latch until the controller frees it. The door's own lock and handle are untouched.
  • Magnetic lock An electromagnet on the frame and a steel plate on the door. It holds only while current flows, usually with 600 or 1,200 pounds of force. Often called a maglock.
  • Electrified lock A lock inside the door whose outside handle is locked or freed electrically. Power reaches it through a special hinge. Push bars on exit doors can be electrified in the same way.

One idea ties them together. A door is only locked if it is closed and held. Strikes and electrified locks rely on the door's latch to hold it, so the door must swing shut and latch by itself. A magnetic lock needs no latch, which is its attraction and its weakness.

Side by side

Electric strikeMagnetic lockElectrified lock
Without powerUsually stays locked. Fail-safe versions exist.Always unlocksEither, chosen when ordering
Getting outTurn the handleNeeds a sensor and a push button to cut the powerTurn the handle
Work on the doorCut the frameScrew on, no cuttingReplace the lock and fit a power hinge
Moving partsA fewNoneSeveral
Typical costLowestLowHighest

Check yourself

Which lock can never keep a door locked through a power cut without a battery?

Choose a lock for a door

The door decides most of the answer. Pick a door and see what usually fits, and what to check first.

What kind of door is it?

Check first

These are starting points. The final word on any door in an exit route belongs to the local authority having jurisdiction, as lesson 1 explained. Lesson 7 covers those rules in detail.

The electrical side

  • Voltage. Almost all locks run on 12 or 24 volts DC. Many accept either, set by a small switch or by how the wires are joined.
  • Current. A lock draws somewhere between a quarter of an amp and one amp. Motor-driven push bars draw much more for an instant. The power supply must cover every lock that could be on at once. Lesson 8 does the math.
  • Which relay terminal. A lock that needs power to release goes on NO. A lock that needs power to hold goes on NC. Lesson 1 showed why.
  • The kick. A lock is a coil of wire. When its power is switched off, the coil throws a brief spike of high voltage back down the cable. A small part called a suppressor, fitted across the lock's two wires, absorbs it. Without one, the spike slowly destroys the controller's relay.

Why magnetic locks come with extra parts

With a strike or an electrified lock, the inside handle is purely mechanical. Nothing electrical can stop a person leaving. A magnetic lock is different: the only way out is to cut its power. So United States codes generally ask for all of these on a door held by a magnet:

  • A motion sensor inside that releases the lock as someone approaches.
  • A push button beside the door that cuts the lock's power directly, without going through the controller.
  • Release when the fire alarm sounds, and release when power fails.

Three examples

Simple: one office door

A wooden office door has an ordinary handle and latch, and a hollow metal frame. A fail-secure electric strike is fitted in place of the frame's plate. The door looks unchanged, the key still works, and the room stays locked in a power cut.

Medium: the glass entrance

A storefront has a pair of frameless glass doors with pull handles and no latch. There is nothing for a strike to hold. Two magnetic locks go on the header above the doors, with a motion sensor inside, a push button on the wall and a link to the fire alarm.

The owner then asks why the shop is unlocked after a power cut. That is how a magnet behaves. The answer is a battery sized to hold both magnets for as long as the owner needs.

Advanced: the stairwell door

A ten-story office wants card access from the stairwell into each floor. These are fire doors. In a fire they must be closed and latched to keep smoke out of the stairs, so a magnet by itself will not do.

There is a second requirement. If people in the stairwell meet smoke, they need to get back onto a floor. So codes commonly require these doors to unlock from the stair side when the fire alarm sounds, while staying latched. The usual answer is a fire-rated, fail-safe electrified lock: the latch always holds the door shut, and the alarm frees the stair-side handle.

Notice that the safe answer here is fail-safe, on a door where security staff instinctively want fail-secure. This is exactly the kind of door to settle with the AHJ before ordering.

From the field

  • Watch the door close ten times before choosing anything. If it does not latch every time, fix the closer and hinges first.
  • Check for pressure on the latch. If the door seal pushes the latch hard against the keeper, a strike can jam. People learn to pull the door before badging, then complain it is broken.
  • Fit the suppressor at the lock, not at the cabinet. It works best right next to the coil.
  • Keep the magnet and plate clean and flat. A grain of grit or a painted surface between them can cut the holding force by more than half.
  • Carry both voltages in your head. A 12-volt lock on a 24-volt supply burns out. A 24-volt lock on 12 volts holds weakly and nobody notices until it matters.

Common mistakes

  • Choosing a magnetic lock because it is easy to fit, then discovering the exit hardware and approvals it requires.
  • Putting a fail-safe lock on a room that must stay protected in a power cut.
  • Fitting a strike that is not fire-rated into a fire door frame.
  • Wiring the exit push button through the controller, so a controller fault can trap people.
  • Leaving out the suppressor, then replacing a relay a year later.

Summary

  • A strike frees the latch at the frame. A magnet holds the door directly. An electrified lock frees the handle.
  • Strikes and electrified locks need a door that latches by itself.
  • A magnetic lock always unlocks without power, and needs extra exit devices.
  • The door and its place in the exit route decide the lock, more than price does.
  • Every lock is a coil. Match the voltage, size the supply, and fit a suppressor.

Exercises

Answer each one yourself first, then open the answer.

Exercise 1. With an electric strike, does the door's latch move when access is granted?

Show answer
No. The latch stays out. The strike's keeper swings aside and lets the latch pass. Step through the strike in the diagram at the top to see it.

Exercise 2. A magnetic lock goes on which relay terminal with C, and why?

Show answer
NC. The magnet needs power all the time. NC is connected until the relay flips, so granting access cuts the power and releases the door.

Exercise 3. A storeroom door with a fail-secure strike will not open after a power cut, although the cards are valid. Is something broken?

Show answer
No. A fail-secure strike needs power to release. With none, card entry stops. People inside can still turn the handle and leave, and someone outside needs the key. A battery on the power supply avoids the problem.

Exercise 4 (think, don't memorize). A customer wants a magnetic lock on a rear staff door "because it is strongest". The door is solid, has a handle and latch, and leads to a room holding cash. What do you suggest?

Show answer
A fail-secure electric strike or electrified lock. Holding force is not the issue on a door that already latches. What matters is that a magnet would release in a power cut and leave the cash room open, and would need a sensor, a push button and a fire alarm link. The strike keeps the room locked without power and lets people out with the handle.